Siemens 3RH1140-1AN60 — Contactors

Siemens 3RH1140-1AN60 SIRIUS Auxiliary Contactor, 4 NO, Size

MPN3RH1140-1AN60

Siemens SIRIUS auxiliary contactor, Size S00, 4 NO, 10 A AC-12, 45 mm width, screw and snap-on mounting, order code 3RH1140-1AN60.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH1140-1AN60 — Identification
ParameterValue
Contactor frame sizeS00
3RH1140-1AN60 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1140-1AN60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz200 V
3RH1140-1AN60 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1140-1AN60 — Protection & Coordination
ParameterValue
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RH1140-1AN60 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RH1140-1AN60 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1140-1AN60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
3RH1140-1AN60 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

The Siemens 3RH1140-1AN60 is a SIRIUS auxiliary contactor, Size S00, with 4 normally open (NO) instantaneous contacts. It's rated for 10 A at AC-12 duty, which covers the control-circuit switching you'd expect from an auxiliary block — relay coils, contactor coils, PLC digital inputs, that class of load.

The 10 A AC-12 rating is the key number for control-circuit duty — it's the maximum resistive current the contacts can make and break. For inductive loads like contactor coils, derate to the AC-15 values: 6 A at 230 V, 3 A at 400 V, 1 A at 690 V. The 4 NO configuration gives you four independent auxiliary circuits, which is enough to signal 'contactor on' back to a PLC, interlock a second starter, and still have a spare for a local pilot light. Wire termination accepts 2x 0.5-1.5 mm², 2x 0.75-2.5 mm², or 2x 4 mm² solid — that covers standard control wiring up to 12 AWG. The IP20 front protection is typical for inside a panel; no washdown rating here, so keep it behind the enclosure door. Shock resistance is 10g / 5 ms and 5g / 10 ms — fine for normal industrial vibration on a machine base or conveyor section.

The Size S00 footprint is 45 mm wide, 57.5 mm high, 72 mm deep. Zero side clearance required for adjacent devices, so you can butt it against the next S00 contactor or overload relay.

Frequently asked questions

What are the key ratings for 3RH1140-1AN60?

4 NO contacts rated 10 A AC-12. AC-15 ratings: 6 A at 230 V, 3 A at 400 V, 1 A at 690 V. Size S00, 45 mm wide, screw and snap-on DIN rail mount.

Where can I buy 3RH1140-1AN60?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.

What wire sizes does 3RH1140-1AN60 accept?

The terminals accept 2x 0.5-1.5 mm², 2x 0.75-2.5 mm², or 2x 4 mm² solid conductors.