Siemens 3RH1140-1BB40-ZW96 — Contactors

Siemens 3RH1140-1BB40-ZW96 SIRIUS Auxiliary Contactor, 24 V

MPN3RH1140-1BB40-ZW96

Siemens SIRIUS auxiliary contactor, 3RH1140-1BB40-ZW96, 24 V DC coil, 4 NO instantaneous contacts, 10 A rated at 24 V, S00 size, screw and snap-on DIN rail mounting, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH1140-1BB40-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RH1140-1BB40-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1140-1BB40-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RH1140-1BB40-ZW96 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1140-1BB40-ZW96 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1140-1BB40-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1140-1BB40-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1140-1BB40-ZW96 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

The Siemens 3RH1140-1BB40-ZW96 is a SIRIUS auxiliary contactor — a 4-pole, 24 V DC coil device with 4 NO instantaneous contacts, rated 10 A at 24 V. It's built for the S00 contactor frame size, so it shares the 45 mm width and 57.5 mm height of the SIRIUS 3RT1 power contactors, with a 72 mm depth that clears the standard DIN-rail enclosure depth.

The 4 NO contacts are rated for switching at multiple voltages: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, down to 1 A at 690 V. This means the contactor handles signal-level loads (PLC outputs, pilot devices) through to moderate auxiliary circuits in motor starter buckets, as long as the load current stays under the voltage-specific curve. For a Tier-1 line running 24 V PLC inputs, this means the contactor won't introduce nuisance faults on low-level signals.

Wire termination accepts 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm² solid, or the AWG equivalents (2x 20-16, 2x 18-14, 1x 12).

Frequently asked questions

What are the key ratings for this auxiliary contactor?

24 V DC coil, 4 NO contacts rated 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, 1 A at 690 V. Coil holding power is 3.2 W DC. Contact reliability is 1 failure per 100 million operations at 17 V, 1 mA.

What is the physical size and mounting?

S00 frame size: 45 mm wide, 57.5 mm high, 72 mm deep. Mounts on 35 mm DIN rail via screw or snap-on. IP20 front protection. Wire range 0.5 to 4 mm² solid.

MPN
3RH1140-1BB40-ZW96