Skip to main content
Siemens 3RH1140-2AF00-ZW98 — Contactors

Siemens 3RH1140-2AF00-ZW98 SIRIUS Auxiliary Contactor, 4 NO,

MPN3RH1140-2AF00-ZW98

Siemens SIRIUS auxiliary contactor, 3RH1140-2AF00-ZW98, 4 NO instantaneous contacts, size S00, screw and snap-on mounting, IP20, 45 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RH1140-2AF00-ZW98 — Identification
ParameterValue
Contactor frame sizeS00
3RH1140-2AF00-ZW98 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1140-2AF00-ZW98 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RH1140-2AF00-ZW98 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1140-2AF00-ZW98 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1140-2AF00-ZW98 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1140-2AF00-ZW98 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1140-2AF00-ZW98 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

Siemens SIRIUS auxiliary contactor 3RH1140-2AF00-ZW98. Four NO instantaneous contacts, size S00 frame — the smallest SIRIUS footprint. Screw and snap-on mounting to DIN rail, 45 mm wide. IP20 front protection, so it lives inside the enclosure, not on the panel face.

Rated for 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V — those are the thermal current limits for the contacts at those voltages. Surge voltage resistance 6 kV, pollution degree 3, so it holds up in industrial panels where conductive dust and humidity are normal.

Mounting and wiring — no surprises

Screw terminals accept 2x 0.25 to 2.5 mm² solid. That covers most DIN-rail layouts without needing a special bracket.

Frequently asked questions

What is the contact configuration?

Four NO (normally open) instantaneous contacts. No leading, lagging, delayed, or make-before-break switching.

What is the physical size and mounting?

Size S00 frame, 45 mm wide, 60 mm high, 73 mm deep. Screw and snap-on mounting to DIN rail.

What are the key current ratings?

10 A at 24 V, 6 A at 230 V, 3 A at 400 V, 1 A at 110 V (AC), 0.27 A at 220 V.

What is the ambient temperature range?

Operation: -25 to +60 °C. Storage and transport: -55 to +80 °C.

MPN
3RH1140-2AF00-ZW98