Siemens 3RH1140-2AP00-ZW97 — Contactors

Siemens SIRIUS 3RH1140-2AP00-ZW97 Auxiliary Contactor, 4 NO,

MPN3RH1140-2AP00-ZW97

Siemens SIRIUS auxiliary contactor, 3RH1140-2AP00-ZW97, 4 NO contacts, size S00, screw and snap-on mounting, IP20 front protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RH1140-2AP00-ZW97 — Identification
ParameterValue
Contactor frame sizeS00
3RH1140-2AP00-ZW97 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1140-2AP00-ZW97 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RH1140-2AP00-ZW97 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1140-2AP00-ZW97 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1140-2AP00-ZW97 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1140-2AP00-ZW97 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1140-2AP00-ZW97 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

It is designed to switch control and signal circuits in motor control centers and distribution panels, typically driven by a larger power contactor or PLC output to extend the number of auxiliary contacts available for status feedback, interlocks, or logic wiring. The S00 footprint keeps it compact at 45 mm wide, 60 mm tall, and 73 mm deep — a common size that slots into existing panel layouts without re-spacing.

The 4 NO contacts are rated for 10 A at 24 V, dropping to 6 A at 230 V and 3 A at 400 V. This means the contactor handles higher currents at lower control voltages, typical for pilot-duty signaling, and derates predictably as line voltage rises. The 6 kV rated surge voltage resistance indicates the contacts can withstand transient overvoltages common in industrial environments without welding or arcing over. Contact reliability is specified as one incorrect switching operation per 100 million cycles at 17 V, 1 mA — a dry-circuit rating that matters when switching low-energy signals like PLC inputs or sensor feedback. If the signal level is that low, the contacts will hold a clean circuit without needing gold plating or sealed relays. Pollution degree 3 confirms it tolerates conductive pollution typical of control rooms and light industrial floors.

The auxiliary switch extension is supported, meaning you can add more contact blocks on top of the base 4 NO configuration without replacing the contactor. This is useful when a panel revision adds feedback points after the initial build.

Integration notes

Wire capacity is 2x (0.25 to 2.5 mm²) solid or stranded — standard for control wiring. Terminals accept ferruled conductors; strip length is typical for screw-clamp terminals. Shock resistance is rated at 10g for 5 ms and 5g for 10 ms, which is sufficient for mounting on a panel door or inside a cabinet near vibrating machinery like pumps or conveyors. The contactor will not drop out or chatter under normal industrial vibration.

Frequently asked questions

What are the key dimensions of this auxiliary contactor?

Width is 45 mm, height is 60 mm, and depth is 73 mm. It is a size S00 footprint that fits standard DIN-rail spacing.

What wire sizes does the terminal accept?

Each terminal accepts 2 conductors of 0.25 to 2.5 mm² solid or stranded wire. Use ferrules for stranded conductors to avoid stray strands.

Can this contactor be used as a direct drop-in replacement for the 3RT1017-1AP01?

The 3RH1140-2AP00-ZW97 is an auxiliary contactor with 4 NO contacts, while the 3RT1017-1AP01 is a power contactor with a coil and main contacts. They serve different functions — the 3RH1140 extends auxiliary contacts from a power contactor or PLC, not replace it. Panel wiring and function differ.