Siemens 3RH1921-1LA02 Auxiliary Switch Block, 2 NC, 10 A, SI

MPN3RH1921-1LA02

Siemens SIRIUS auxiliary switch block, 3RH1921-1LA02, 2 NC, screw terminals, 10 A max, for 3RT1 contactors.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH1921-1LA02 — Ratings & Performance
ParameterValue
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH1921-1LA02 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1921-1LA02 — Connection & Mounting
ParameterValue
Mounting methodsnap-on mounting
3RH1921-1LA02 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
3RH1921-1LA02 — Mechanical
ParameterValue
Width44 mm
Height38 mm
Depth51 mm

Product details

It carries a maximum thermal current of 10 A and is rated for AC-15 and DC-13 switching duties across a range of control voltages: 6 A at 24 V, 6 A at 125 V, 6 A at 230 V, and 3 A at 400 V, among others. The screw-type terminals accept 2x (0.5…1.5 mm²) or 2x (0.75…2.5 mm²) with core-end processing, or 2x (20…16) and 2x (18…14) AWG.

Snap-on mounting onto the contactor body — no DIN rail required for the block itself, though the base contactor typically mounts on a 35 mm rail. The block adds 44 mm width, 38 mm height, and 51 mm depth to the assembly. Front-side IP20 protection means it is safe for finger contact inside an enclosed panel but not for exposed washdown areas.

The AC-15 ratings (6 A at 230 V, 3 A at 400 V, 1 A at 690 V) govern solenoid and contactor coil switching — the most common load for an auxiliary block. The DC-13 ratings (10 A at 24 V, 4.7 A at 60 V, 3 A at 110 V, 1.2 A at 220 V, 0.5 A at 440 V, 0.26 A at 600 V) cover DC electromagnet loads with a time constant. If your control circuit operates at 24 VDC and pulls more than 10 A inrush, this block is not a fit.

Frequently asked questions

Will 3RH1921-1LA02 drop into a panel specified around 3RH2422-1AB00 without rewiring?

Not directly. The 3RH2422-1AB00 is a standalone auxiliary contactor with its own coil (AC-operated, 24 V, 50/60 Hz) and a different footprint (90 mm wide vs 44 mm for the switch block). The 3RH1921-1LA02 is a snap-on block for a 3RT1 base contactor, not a self-contained contactor. If the panel is wired for a 3RH2422-1AB00, you would need to re-engineer the mounting and control circuit.

What does the note 'with 3RT1' mean?

It means this auxiliary switch block is designed to mount directly onto 3RT1 series contactors and contactor relays. It is not a standalone device.

What is the depth of 3RH1921-1LA02?

51 mm, measured from the mounting face of the contactor.