Skip to main content
Siemens 3RH2122-2LF40-0LA0 — Contactors

Siemens 3RH2122-2LF40-0LA0 SIRIUS Auxiliary Contactor, S00

MPN3RH2122-2LF40-0LA0
Active

Siemens SIRIUS 3RH2122-2LF40-0LA0 auxiliary contactor, size S00, 2 NO instantaneous contacts, 110 V DC coil with varistor, screw and snap-on 35 mm DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH2122-2LF40-0LA0 — Identification
ParameterValue
Contactor frame sizeS00
3RH2122-2LF40-0LA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2122-2LF40-0LA0 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RH2122-2LF40-0LA0 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2122-2LF40-0LA0 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail
3RH2122-2LF40-0LA0 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH2122-2LF40-0LA0 — Environmental
ParameterValue
Operating temperature range-40 ... +70 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH2122-2LF40-0LA0 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth116 mm
3RH2122-2LF40-0LA0 — Specifications
ParameterValue
At AC10 000 1/h

Product details

S00 auxiliary contactor with 2 NO and a 110 V DC coil

The Siemens 3RH2122-2LF40-0LA0 is a SIRIUS auxiliary contactor in frame size S00, carrying 2 normally-open instantaneous contacts and a 110 V DC coil with an integrated varistor surge suppressor. The varistor across the coil suppresses the inductive kick when the DC circuit opens, protecting the PLC output or control relay driving it.

Switching performance and endurance

Mechanical endurance is 30 million operating cycles typical — this is the life of the mechanism before wear, not the electrical life under load, which will be lower at rated current. Switching frequency: 10,000 operations per hour for AC loads; for DC loads the minimum off-time is 7 to 20 ms, which limits the maximum switching rate to about 50 Hz depending on the load time constant.

Environmental limits and wiring

Relative humidity minimum is 10 %; no upper limit stated in the record, but the SIRIUS series typically handles up to 95 % non-condensing in standard industrial environments.

The auxiliary switch extension is available as a separate add-on module, so the 2 NO base can be expanded in the field without replacing the contactor.

MPN
3RH2122-2LF40-0LA0