Siemens SIRIUS 3RH2122-4BG40 auxiliary contactor, size S00, 2 instantaneous contacts, 45 mm width, screw and snap-on 35 mm DIN rail mounting, 10 A at 24 V DC rated value.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RH2122-4BG40 — Identification
ParameterValue
Contactor frame sizeS00
3RH2122-4BG40 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2122-4BG40 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RH2122-4BG40 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2122-4BG40 — Connection & Mounting
ParameterValue
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail
3RH2122-4BG40 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH2122-4BG40 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH2122-4BG40 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth73 mm
3RH2122-4BG40 — Specifications
ParameterValue
At AC10 000 1/h

Product details

Panel fit and switching capacity

The 3RH2122-4BG40: Mechanical endurance is 30,000,000 cycles typical, which suits high-cycle applications like conveyor interlocks or valve position feedback where the contactor outlasts the machine service interval.

Coil and switching characteristics

The DC magnet coil draws 4 W both closing and holding — no inrush spike, so the PLC output or relay driving it sees a steady load, and the 6 kV rated surge voltage resistance means it handles transient spikes from inductive loads without external suppression in most cases. Rated control supply voltage is 125 V with an initial value factor of 0.8 and full-scale factor of 1.1 — the coil will pick up at 100 V and hold at 137.5 V, so a sagging 120 V control bus still keeps it engaged.

It supports auxiliary switch extension, meaning you can add front-mounted switch blocks without changing the base contactor — useful if the control scheme evolves after the panel is built. RoHS compliance is dated 10/01/2009, so it meets the EU substance restrictions that apply to most industrial equipment shipped into Europe or following IEC standards.