Siemens 3RH2131-1BB40-ZX95 — Contactors

Siemens SIRIUS 3RH2131-1BB40-ZX95 Auxiliary Contactor, 24 VD

MPN3RH2131-1BB40-ZX95
Active

Siemens SIRIUS auxiliary contactor, size S00, 24 VDC coil, 3 NO contacts, screw and snap-on mounting on 35 mm DIN rail, 45 x 57.5 x 73 mm (WxHxD).

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH2131-1BB40-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RH2131-1BB40-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2131-1BB40-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RH2131-1BB40-ZX95 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2131-1BB40-ZX95 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail
3RH2131-1BB40-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH2131-1BB40-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH2131-1BB40-ZX95 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth73 mm
3RH2131-1BB40-ZX95 — Specifications
ParameterValue
At AC10 000 1/h

Product details

The Siemens SIRIUS 3RH2131-1BB40-ZX95 is a size S00 auxiliary contactor with a 24 VDC coil and three normally open instantaneous contacts. The 24 VDC coil draws 4 W closing and 4 W holding, so the control transformer or PLC output driving it should be sized for that inrush without sag.

The three NO contacts are rated for switching at multiple voltage levels: 10 A at 24 V, 10 A at 230 V, 3 A at 400 V, 1 A at 690 V, and 0.5 A at 440 V. These ratings cover AC loads across common industrial voltages — the 10 A at 230 V is typical for general-purpose control circuits, while the 3 A at 400 V suits three-phase motor control circuits. The contacts also carry DC ratings: 10 A at 24 V, 4.7 A at 60 V, 3 A at 110 V, 1.2 A at 220 V, 0.26 A at 600 V. The arcing time is 10 to 15 ms, and the maximum mechanical switching frequency is 10,000 cycles per hour at AC.

Mounting and environmental

Mounting position is flexible: the contactor can be rotated ±180° on a vertical surface and tilted forward or backward by ±22.5°. Clearances required: 10 mm upwards, 10 mm forwards, 10 mm downwards, and 6 mm at the side. Operating temperature range is -25 to +60 °C; storage range is -55 to +80 °C. Pollution degree 3 (industrial environment with conductive pollution). Relative humidity minimum 10 %. The contactor accepts wire cross-sections from 2x 0.5 mm² up to 2x 4 mm² solid or stranded.

Frequently asked questions

What is the closest functional second-source for 3RH2131-1BB40-ZX95?

The closest functional peer is the 3RH2122-1BA40, which has the same size S00 and 24 VDC coil but with 2 NO + 2 NC contacts instead of 3 NO. The 3RH2131-1BB40-ZX95 provides three normally open contacts; if your circuit requires a mix of NO and NC, the 3RH2122-1BA40 may be a direct drop-in alternative, but verify the contact configuration matches your schematic.

Will 3RH2131-1BB40-ZX95 drop into a panel specified around 3RH2122-1BA40 without rewiring?

Yes, both are size S00, same 45 mm width, same screw and snap-on mounting on 35 mm DIN rail, and same 24 VDC coil. The only difference is contact arrangement: 3 NO vs 2 NO + 2 NC. If your circuit uses only NO contacts, it is a direct swap. If it uses NC contacts, you would need to rewire or choose a different variant.

How do I get current pricing and availability for 3RH2131-1BB40-ZX95?

Submit an RFQ — this part is sourced and quoted to order through independent distribution, with availability and current pricing confirmed at quote time.