Skip to main content
Siemens 3RH2131-1VB40-ZW96 — Contactors

Siemens 3RH2131-1VB40-ZW96 SIRIUS Coupling Relay, 24 VDC, 10

MPN3RH2131-1VB40-ZW96
Active

Siemens SIRIUS coupling relay, 3RH2131-1VB40-ZW96, 24 VDC coil, 10 A rated, 3 instantaneous contacts, Size S00, screw and snap-on mounting onto 35 mm standard mounting rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH2131-1VB40-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RH2131-1VB40-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2131-1VB40-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RH2131-1VB40-ZW96 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2131-1VB40-ZW96 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail
3RH2131-1VB40-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
3RH2131-1VB40-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +50 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH2131-1VB40-ZW96 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth73 mm
3RH2131-1VB40-ZW96 — Specifications
ParameterValue
At AC10 000 1/h

Product details

It carries 3 instantaneous contacts rated at 10 A at 24 V, with a 24 V DC coil drawing 1.6 W closing power. The built-in diode surge suppressor handles coil suppression — no external free-wheel diode needed.

The mounting position is flexible: ±180° rotation on a vertical surface, plus ±22.5° tilt forward/backward. Clearance requirements are tight — 10 mm upward, 10 mm forward, 10 mm downward, and 6 mm at the side. Panel builders can plan for a 45 mm wide × 57.5 mm tall × 73 mm deep envelope.

Frequently asked questions

What are the key ratings of the 3RH2131-1VB40-ZW96?

24 V DC coil, 10 A rated switching at 24 V, 3 instantaneous contacts, Size S00, with a diode surge suppressor. Operating temperature range -25 to +50 °C; storage -55 to +80 °C.

MPN