Skip to main content
Siemens 3RH2140-1AT60 — Contactors

Siemens 3RH2140-1AT60 SIRIUS Auxiliary Contactor, 4 NO, S00

MPN3RH2140-1AT60
Active

Siemens SIRIUS 3RH2140-1AT60 auxiliary contactor, 4 instantaneous NO contacts, size S00, screw and snap-on 35 mm DIN rail mounting, 73 x 45 x 57.5 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RH2140-1AT60 — Identification
ParameterValue
Contactor frame sizeS00
3RH2140-1AT60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2140-1AT60 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RH2140-1AT60 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2140-1AT60 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail
3RH2140-1AT60 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH2140-1AT60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH2140-1AT60 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth73 mm
3RH2140-1AT60 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

S00 auxiliary contactor, 4 NO, DIN rail

The 3RH2140-1AT60: This is the contactor that mirrors the main contactor's coil signal to the control logic — four independent NO circuits, each rated for the full switching capacity of the S00 platform. The 6 kV rated surge voltage resistance (per IEC 60947-1) means this contactor handles the transient spikes common in industrial control panels fed by long cable runs.

Switching performance and endurance

At DC-12 load, maximum operating frequency is 1,000 operations per hour. The relative humidity floor is 10%. The product extension auxiliary switch option (yes) means this base unit accepts additional front-mounted switch blocks if the four built-in NO contacts aren't enough.

RoHS compliance date (substance prohibition) is 10/01/2009 — the part meets the EU RoHS directive effective from that date.

MPN
3RH2140-1AT60