Skip to main content
Siemens 3RH2140-1BE80 — Contactors

Siemens 3RH2140-1BE80 SIRIUS Auxiliary Contactor, 4 N/O, 24

MPN3RH2140-1BE80
Active

Siemens SIRIUS auxiliary contactor, Size S00, 4 N/O instantaneous contacts, 24 VDC coil, screw and snap-on mounting on 35 mm DIN rail, 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH2140-1BE80 — Identification
ParameterValue
Contactor frame sizeS00
3RH2140-1BE80 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2140-1BE80 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RH2140-1BE80 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2140-1BE80 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail
3RH2140-1BE80 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH2140-1BE80 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH2140-1BE80 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth73 mm
3RH2140-1BE80 — Specifications
ParameterValue
At AC10 000 1/h

Product details

The 24 VDC coil draws 4 W closing and holding, so the control transformer sizing is straightforward — no inrush spike beyond the holding power.

Rated operational current at 24 V is 10 A; at 230 V it's also 10 A, but at 400 V it drops to 3 A, and at 690 V it's 1 A. The 10 A rating at 24 V and 230 V covers most control-circuit loads — relay coils, pilot lights, PLC inputs — while the 3 A at 400 V and 1 A at 690 V handle switching of small contactor coils or valve solenoids in higher-voltage panels.

Frequently asked questions

Does 3RH2140-1BE80 drop into a panel designed for 3RH2140-1BP40?

Both are Size S00, 45 mm wide, snap-on DIN rail — same mechanical footprint. The difference is the coil voltage; the -1BE80 is 24 VDC, the -1BP40 is a different coil variant. No rewiring of the mounting or bus structure needed.

Where can I buy 3RH2140-1BE80?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request for a firm quotation.

MPN
3RH2140-1BE80