Siemens 3RH2244-2BB40 — Contactors

Siemens 3RH2244-2BB40 SIRIUS Auxiliary Contactor, 45mm

MPN3RH2244-2BB40
Active

Siemens SIRIUS 3RH2244-2BB40 auxiliary contactor, size S00, 4 NO instantaneous contacts, 24 VDC coil, screw and snap-on 35 mm DIN rail mounting, 45 mm width.

$33.02Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RH2244-2BB40 — Identification
ParameterValue
Contactor frame sizeS00
3RH2244-2BB40 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2244-2BB40 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RH2244-2BB40 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2244-2BB40 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail
3RH2244-2BB40 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
3RH2244-2BB40 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH2244-2BB40 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth121 mm
3RH2244-2BB40 — Specifications
ParameterValue
At AC10 000 1/h

Product details

Panel fit and mounting constraints

The 3RH2244-2BB40: Its 45 mm width and 121 mm depth mean it occupies one standard modular unit on the rail, leaving room for adjacent devices in a crowded panel.

Rated current and contact configuration

This contactor carries 4 normally-open instantaneous contacts. That derating curve means the contactor's thermal capacity is the limiting factor at higher voltages — not the contact material itself. For a 400 V control circuit, budget 3 A per contact as the continuous rating. The coil is 24 VDC with a closing power and holding power of 4 W each. That low holding power means the coil won't overheat in a sealed enclosure, but the inrush at pickup is the same 4 W — no extra surge to stress a 24 VDC power supply.

The substance prohibition date of October 1, 2009 aligns with RoHS compliance for that vintage. Arcing time is 10-15 ms at AC and 7-13 ms at DC. That arc duration is short enough to avoid contact welding in most inductive load applications, but the DC arcing time is tighter — factor that into the contactor's DC switching capability.

Frequently asked questions

What is the 3RH2244-2BB40 rated current at 400 V?

This is the continuous current each normally-open contact can carry at that voltage level.

MPN
3RH2244-2BB40