Siemens 3RH2344-1AP00-0KA0 — Contactors

Siemens 3RH2344-1AP00-0KA0 SIRIUS Auxiliary Contactor, 4 NO

MPN3RH2344-1AP00-0KA0
Active

Siemens SIRIUS 3RH2344-1AP00-0KA0 auxiliary contactor, size S00, 4 NO instantaneous contacts, screw and snap-on mounting on 35 mm DIN rail, 117 mm depth, 45 mm width, 57.5 mm height.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RH2344-1AP00-0KA0 — Identification
ParameterValue
Contactor frame sizeS00
3RH2344-1AP00-0KA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2344-1AP00-0KA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RH2344-1AP00-0KA0 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2344-1AP00-0KA0 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail
3RH2344-1AP00-0KA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
3RH2344-1AP00-0KA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH2344-1AP00-0KA0 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth117 mm
3RH2344-1AP00-0KA0 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

What the 4 NO contacts and 10 A rating mean for your control circuit

The 3RH2344-1AP00-0KA0 is a SIRIUS auxiliary contactor with four normally-open instantaneous contacts, meaning it switches four separate control circuits simultaneously without any built-in delay. For a 24 VDC PLC output or relay interposing circuit, those four NO poles give you plenty of isolation between signals without needing a separate terminal block. The contactor is rated for 10 million mechanical operations typical, so in a machine that cycles once per minute you are looking at roughly 19 years of service before the mechanism wears out. The arcing time sits between 10 and 15 ms, which is standard for this class of auxiliary contactor and means the downstream PLC input filter needs to be set longer than that to catch a clean signal.

Panel fit and DIN rail mounting — size S00 footprint

That means you can pack these side-by-side on the rail with just a finger's width between them, which matters when you are squeezing a dozen auxiliary contactors into a small sub-panel.

Lifecycle and sourcing — still in current production

That means you can spec it into a new BOM without worrying about a last-time-buy window closing. For volume purchases or project quotes, this part is sourced through authorized distribution channels and quoted to order against your BOM quantity; lead time and pricing are confirmed at RFQ time.

Frequently asked questions

What is the 3RH2344-1AP00-0KA0 used for?

It is an auxiliary contactor — it switches control signals rather than motor loads. The four NO contacts are typically used to extend PLC outputs, interlock safety circuits, or signal status back to a controller. In a motor starter setup, it can be mechanically interlocked with a main contactor to provide auxiliary feedback contacts.

What are the operating temperature limits for this contactor?

The relative humidity minimum is 10 %. These limits cover most indoor industrial panel environments without derating concerns.