Siemens 3RH2353-1CG60-0KA0 — Contactors

Siemens 3RH2353-1CG60-0KA0 SIRIUS Auxiliary Contactor, 5 NO

MPN3RH2353-1CG60-0KA0
Active

Siemens SIRIUS auxiliary contactor, 3RH2353-1CG60-0KA0, size S00, 5 normally open instantaneous contacts, screw and snap-on mounting on 35 mm DIN rail, 117 x 45 x 57.5 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RH2353-1CG60-0KA0 — Identification
ParameterValue
Contactor frame sizeS00

Ratings & Performance

3RH2353-1CG60-0KA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A

Control & Coil

3RH2353-1CG60-0KA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz100 V

Contacts & Poles

3RH2353-1CG60-0KA0 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)

Connection & Mounting

3RH2353-1CG60-0KA0 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail

Durability

3RH2353-1CG60-0KA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000

Environmental

3RH2353-1CG60-0KA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m

Mechanical

3RH2353-1CG60-0KA0 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth117 mm

Specifications

3RH2353-1CG60-0KA0 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

Panel fit and contact ratings

The 3RH2353-1CG60-0KA0: Its 5 normally open instantaneous contacts handle the logic-level loads that signal PLC inputs, relay coils, and contactor holding circuits.

Switching performance and environment

The maximum switching frequency for DC loads is 10,000 operations per hour — above that the contact erosion rate accelerates. For AC loads at 50 Hz the operating range factor is 0.8–1.1, and at 60 Hz it is 0.85–1.1, meaning the contactor picks up reliably between 80% and 110% of rated control supply voltage. Minimum relative humidity is 10%.