Skip to main content
Siemens 3RH2911-1DA02 — Contactors

Siemens 3RH2911-1DA02 SIRIUS S00 Auxiliary Switch

MPN3RH2911-1DA02
Active

Siemens SIRIUS 3RH2911-1DA02 auxiliary switch, size S00, first laterally mountable, snap-on DIN rail, 10 mm width, 66 mm depth, 57.4 mm height, IP20 front.

$6.48Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RH2911-1DA02 — Identification
ParameterValue
Contactor frame sizeS00
3RH2911-1DA02 — Ratings & Performance
ParameterValue
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2911-1DA02 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2911-1DA02 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodsnap-on mounting
3RH2911-1DA02 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
3RH2911-1DA02 — Mechanical
ParameterValue
Width10 mm
Height57.4 mm
Depth66 mm

Product details

S00 auxiliary switch for contactor relay and power contactor duty

The Siemens 3RH2911-1DA02 is a SIRIUS S00 auxiliary switch designed for lateral snap-on mounting alongside contactor relays and power contactors in the S00 frame size. At 10 mm wide, it occupies one slot on the DIN rail — the narrowest footprint in the SIRIUS auxiliary range — so it fits into densely packed panels where every millimeter matters for gland-plate fill factor. Rated operational current at 24 V is 6 A; at 230 V it delivers 6 A; at 400 V it switches 3 A. The AC-15 rated values for contactor relay duty are higher — 10 A at 24 V, 3 A at 110 V, 1.2 A at 220 V — reflecting the inductive load switching capability for solenoid and contactor coils.

Contact reliability and mirror contact compliance

The auxiliary contacts are rated for 1 faulty switching per 100 million operations at 17 V, 1 mA — this is the dry-circuit reliability floor for PLC-level signals where oxidation on unmated contacts can cause intermittent faults. The switch also qualifies as a mirror contact per IEC 60947-4-1 when used with 3RT2 contactors, meaning the NC position mechanically reflects the main contact state for safety circuit isolation. Surge voltage resistance is 6 kV, covering the impulse voltage withstand for 400 VAC industrial networks per IEC 60947-1 overvoltage category III. This matters when the switch is wired in a safety chain that must survive transient events without false triggering.

Current production — sourcing and compliance

Sourced and quoted to order against the BOM quantity through independent distribution. Availability and current pricing confirmed at RFQ time — no stock-holding claim is made here.

MPN
3RH2911-1DA02