Siemens 3RH2911-1HA02-ZW98 — Contactors

Siemens 3RH2911-1HA02-ZW98 Auxiliary Switch, 2 NC, 10 A

MPN3RH2911-1HA02-ZW98
Active

Siemens SIRIUS 3RH2911-1HA02-ZW98 auxiliary switch block, 2 NC contacts, 10 A maximum, screw-type terminals, snap-on mounting for 3RT2 contactors and 3RH2 contactor relays.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Ratings & Performance

3RH2911-1HA02-ZW98 — Ratings & Performance
ParameterValue
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A

Contacts & Poles

3RH2911-1HA02-ZW98 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)

Connection & Mounting

3RH2911-1HA02-ZW98 — Connection & Mounting
ParameterValue
Mounting methodsnap-on mounting

Environmental

3RH2911-1HA02-ZW98 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C

Mechanical

3RH2911-1HA02-ZW98 — Mechanical
ParameterValue
Width36 mm
Height37.5 mm
Depth43.7 mm

Product details

What this auxiliary switch does on a 3RT2 or 3RH2 base

The 3RH2911-1HA02-ZW98: This is a front-mounted auxiliary switch block for Siemens SIRIUS contactors (3RT2) and contactor relays (3RH2). It adds two normally-closed (NC) contacts to the base device, wired via screw-type terminals that accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) conductors, or 2x (20 to 16) and 2x (18 to 14) AWG. The snap-on mounting means it clips directly onto the front of the contactor or relay without tools — no extra DIN rail space needed. The IP20 front protection is standard for enclosed panels; keep the panel door closed during operation.

Current ratings across the voltage range — what they mean for your circuit

The maximum thermal current is 10 A, but the real switching capacity depends on the voltage and load type. At 24 V AC-15 (solenoid/contactor coil duty) it switches 6 A; at 230 V AC-15 it handles 6 A; at 400 V AC-15 it drops to 3 A. For DC loads, the 24 V rated value is 10 A, but at 220 V DC it falls to 1.2 A, and at 600 V DC it's just 0.26 A. The contact reliability spec — one faulty switching per 100 million operations at 17 V, 1 mA — means this switch handles low-signal PLC inputs reliably, not just power circuits. The mechanical life of 10 million switching cycles covers most panel applications for years.

Panel fit and environmental limits

Dimensions are 36 mm wide, 37.5 mm high, 43.7 mm deep — it adds about 44 mm to the front of the contactor. Operating temperature range is -25 to +60 °C; storage range is -55 to +80 °C. The insulation voltage is rated 690 V AC with pollution degree 3, and surge voltage resistance is 6 kV — suitable for 400 V line-to-line panels with proper clearance.

Frequently asked questions

What is the 3RH2911-1HA02-ZW98's contact configuration?

It provides two normally-closed (NC) auxiliary contacts, wired via screw-type terminals. The contact sequence is 1 NC, 1 NC.

What wire sizes fit the screw terminals?

The terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) conductors, and 2x (20 to 16) or 2x (18 to 14) AWG.

MPN
3RH2911-1HA02-ZW98