Siemens 3RH2911-2DA02-ZX95 — Contactors

Siemens 3RH2911-2DA02-ZX95 SIRIUS Auxiliary Switch, 10 A at

MPN3RH2911-2DA02-ZX95

Siemens SIRIUS auxiliary switch, 3RH2911-2DA02-ZX95, snap-on mounting for size S00 contactor relays and power contactors, 10 A at 24 V rated, mirror contact per IEC 60947-4-1, IP20 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RH2911-2DA02-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RH2911-2DA02-ZX95 — Ratings & Performance
ParameterValue
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2911-2DA02-ZX95 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2911-2DA02-ZX95 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodsnap-on mounting
3RH2911-2DA02-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
3RH2911-2DA02-ZX95 — Mechanical
ParameterValue
Width10 mm
Height64.8 mm
Depth66 mm

Product details

It is the first laterally mountable design in the series, meaning it clips onto the side of the contactor without occupying additional DIN rail space — a detail that matters when you're packing contacts into a tight panel and every millimeter of rail width counts. At 10 mm wide, 64.8 mm tall, and 66 mm deep, it tucks into the same envelope as the contactor itself. The IP20 front protection is standard for enclosed panel gear — no washdown rating here, so keep it behind a gland plate or enclosure door.

It carries a mirror contact per IEC 60947-4-1 when used with 3RT2 contactors. That means the normally closed contact mechanically mirrors the main contactor's state — critical for safety circuits where you need positive indication that the power contacts have opened. That's a solid number for PLC input sensing. The leading and lagging contacts are both zero — meaning all contacts switch simultaneously, no overlap timing for sequenced signaling.

Terminals accept 2 x (0.5 to 2.5 mm²) solid or stranded, or 2 x (20 to 14 AWG). For finely stranded wire with ferrule, it's 2 x (0.5 to 1.5 mm²).

Substance prohibition date is 10/01/2009, which aligns with the original EU RoHS directive (2002/95/EC). The part is RoHS-compliant as shipped. No UL or CSA listing appears in the evidence, but the IEC 60947-4-1 mirror contact reference implies it is designed to that international standard. For a compliance pack, request the manufacturer's declaration from your sourcing contact.