Siemens 3RH2911-4HA01 SIRIUS Auxiliary Switch, snap-on, 10A

MPN3RH2911-4HA01

Siemens SIRIUS auxiliary switch, 3RH2911-4HA01, snap-on front mounting for contactor sizes S00, S0, S2, S3, ring terminal lug connection, rated 10 A AC-12, 6 kV surge voltage resistance.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH2911-4HA01 — Identification
ParameterValue
Contactor frame sizeS00, S0, S2, S3
3RH2911-4HA01 — Ratings & Performance
ParameterValue
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2911-4HA01 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2911-4HA01 — Connection & Mounting
ParameterValue
Mounting methodsnap-on mounting
3RH2911-4HA01 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
3RH2911-4HA01 — Mechanical
ParameterValue
Width36 mm
Height37.5 mm
Depth43.7 mm

Product details

The Siemens 3RH2911-4HA01 is a SIRIUS auxiliary switch designed for snapping onto the front of contactor relays and power contactors in sizes S00, S0, S2, and S3. Contact reliability is 1 faulty switching per 100 million at 17 V and 1 mA. The ring terminal lug connection means wiring is done with crimped ring terminals, not spring-cage or screw-clamp — factor that into your panel wiring method and terminal strip planning.

Rated operational current at AC-12 (resistive load) is 10 A maximum, and at AC-15 (inductive load typical of contactor coils) it's 1 A at 690 V — so this switch handles control-circuit isolation for the contactor itself, not motor power. The AC-15 current ratings across common control voltages are: 6 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V and 250 V, and 3 A at 400 V — these are the values that govern whether the auxiliary contacts can reliably switch the connected pilot devices or PLC inputs without welding. The mirror contact feature per IEC 60947-4-1 is critical for safety circuits: when used with 3RT2 contactors, the normally-closed mirror contact cannot remain closed if the main contacts weld, providing a reliable feedback path for the safety relay or PLC. Surge voltage resistance rated at 6 kV means the auxiliary switch withstands transient overvoltages typical of industrial control panels without flashover — important for maintaining isolation integrity in mixed-voltage cabinets.

Specify the order code, confirm the contactor frame size (S00 through S3), and the snap-on front mount plus ring terminal connection are fixed.

Snap-on mounting onto the front of the contactor means no DIN rail space is consumed — the auxiliary switch rides on the contactor itself, keeping the panel layout compact. Dimensions are 36 mm wide, 43.7 mm deep, 37.5 mm high — verify clearance in front of the contactor for the ring terminal wiring access, especially in dense panels. Operating temperature range is -25 to +60 °C, storage -55 to +80 °C — adequate for most indoor industrial control panels, but check if your enclosure ambient exceeds 60 °C near heat sources like drives or transformers.

Frequently asked questions

What contactor sizes does this auxiliary switch fit?

It fits SIRIUS contactor sizes S00, S0, S2, and S3, covering a wide range of motor starter frames from small to medium.

What is the contact reliability specification?

The auxiliary contacts are rated for 1 faulty switching per 100 million operations at 17 V and 1 mA, indicating very high reliability for dry switching of PLC inputs or low-energy signals.

Does this switch have mirror contact functionality?

Yes, it is a mirror contact according to IEC 60947-4-1 when used with 3RT2 contactors, providing a mechanically linked normally-closed contact that reflects the main contact status for safety circuits.

What type of electrical connection does it use?

It uses ring terminal lug connection for the auxiliary and control circuits, requiring crimped ring terminals rather than ferrules or bare wire under a screw clamp.

MPN
3RH2911-4HA01