Siemens 3RH2911-4HA31 — Contactors

Siemens SIRIUS 3RH2911-4HA31 Auxiliary Switch, 3 NO + 0 NC,

MPN3RH2911-4HA31

Siemens SIRIUS 3RH2911-4HA31 auxiliary switch, 3 NO instantaneous contacts, snap-on front mounting for S00/S0/S2/S3 contactors, ring terminal lug connection, 43.7 mm depth, IP00 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RH2911-4HA31 — Identification
ParameterValue
Contactor frame sizeS00, S0, S2, S3
3RH2911-4HA31 — Ratings & Performance
ParameterValue
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2911-4HA31 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2911-4HA31 — Connection & Mounting
ParameterValue
Mounting methodsnap-on mounting
3RH2911-4HA31 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
3RH2911-4HA31 — Mechanical
ParameterValue
Width36 mm
Height37.5 mm
Depth43.7 mm

Product details

The Siemens SIRIUS 3RH2911-4HA31 is a front-mounted auxiliary switch block carrying three normally-open instantaneous contacts. It snaps onto the front of SIRIUS contactors in frame sizes S00, S0, S2, and S3 — that covers the 3RT2 and 3RT1 families from about 7 A up through 300 A motor loads. The ring terminal lug connection means you land ring forks on the screw terminals, not push-on spades or cage clamps; plan your wire prep accordingly.

Three NO contacts, zero NC, zero lagging contacts. If your safety circuit demands a positively-guided NC, this block cannot provide it — you need a different variant. The AC-15 rating at 690 V is 1 A; that is the inductive switching limit for solenoid and contactor coils at high line voltage. At 24 V the AC-15 rating climbs to 10 A, so it handles multiple small contactor coils in parallel without a separate interposing relay. The mirror-contact feature per IEC 60947-4-1 applies when used with 3RT2 contactors — relevant for applications requiring welded-contact detection in motor circuits. That is the dry-circuit threshold — if your signal chain runs at logic-level voltage and milliamps, this block is rated for it.

Snap-on front mounting — no tools, no DIN rail. The block clips directly onto the contactor's front face. Dimensions are 36 mm wide, 43.7 mm deep, 37.5 mm high. The IP00 front rating means no ingress protection on the front face; the contactor's own enclosure provides the panel-level IP rating.

Frequently asked questions

What are the key switching ratings for this auxiliary switch?

Three NO contacts rated AC-15: 10 A at 24 V, 3 A at 110 V, 1.2 A at 220 V, 1 A at 690 V. Also carries 6 A at 24 V for general-purpose switching. Contact reliability is one fault per 100 million operations at 17 V, 1 mA.

What contactors does the 3RH2911-4HA31 fit?

It snaps onto the front of SIRIUS contactors in frame sizes S00, S0, S2, and S3. This covers the 3RT2 and 3RT1 series from small 7 A frames up through the larger 300 A class contactors.

Does this auxiliary switch have mirror contacts?

Yes, the mirror contact feature per IEC 60947-4-1 is confirmed when used with 3RT2 contactors. This is relevant for motor circuits where welded-contact detection is required for safety functions.

What is the connection type on the 3RH2911-4HA31?

Ring terminal lug connection for the auxiliary and control circuits. Wire preparation requires ring terminals, not ferrules or spade connectors.