Skip to main content
Siemens 3RH6140-1AG00 — Contactors

Siemens 3RH6140-1AG00 SIRIUS Contactor Relay, 4 NO

MPN3RH6140-1AG00

Siemens SIRIUS 3RH6140-1AG00 contactor relay, size S00, 4 NO auxiliary contacts, 6 A rated operational current at 230 V AC, 45 mm width, screw and snap-on mounting for 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RH6140-1AG00 — Identification
ParameterValue
Contactor frame sizeS00
3RH6140-1AG00 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.6 A
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V6 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH6140-1AG00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz36 V
3RH6140-1AG00 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH6140-1AG00 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail
3RH6140-1AG00 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH6140-1AG00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH6140-1AG00 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth73 mm
3RH6140-1AG00 — Specifications
ParameterValue
At AC10 000 1/h

Product details

SIRIUS contactor relay — auxiliary switching for control circuits

The 3RH6140-1AG00 is a SIRIUS contactor relay — essentially an auxiliary contactor block with its own coil, used to multiply signal paths in control circuits rather than switch motor loads directly. It carries 4 normally open contacts, identified by the switching element code 40 E. This lets you size the contacts for the specific control voltage on your panel.

Panel fit — DIN rail footprint and wiring

Width is 45 mm, depth 73 mm, height 57.5 mm — size S00 frame. Finely stranded with ferrule also supported. This covers most control wiring gauges used in industrial panels.

Coil specs and control transformer sizing

The coil draws 37 VA apparent power on pick-up and 5.7 VA holding — size your control transformer for the inrush, not the sealed current. Maximum operating frequency under DC-12 and DC-13 duty is 1,000 cycles per hour — the DC arc extinguishes slower, so cycle rate is limited. Surge voltage resistance is 6 kV, covering impulse voltage coordination for 400 V class installations per IEC 60947.

Sourcing and lifecycle — active production, quoted to order

For volume purchases or MRO stock, the 45 mm width and S00 footprint mean it panels into the same slot as other SIRIUS size S00 devices.

Frequently asked questions

What is the contact configuration of 3RH6140-1AG00?

It has 4 normally open auxiliary contacts, identified by switching element code 40 E. There are no NC contacts on this variant.

What voltage does the coil need on 3RH6140-1AG00?

Coil pick-up power is 37 VA, holding power is 5.7 VA.

Can I use 3RH6140-1AG00 for switching DC loads?

Yes, but the maximum operating frequency under DC-12 and DC-13 duty is limited to 1,000 cycles per hour, compared to 10,000 cycles per hour for AC loads. The DC arc extinguishes slower, so cycle rate is reduced.

MPN