Skip to main content
Siemens 3RH6140-1AR60 — Contactors

Siemens 3RH6140-1AR60 SIRIUS Contactor Relay, 4 NO, 6 A

MPN3RH6140-1AR60

Siemens SIRIUS 3RH6140-1AR60 contactor relay, size S00, 4 NO auxiliary contacts, AC coil, 45 mm width, 73 mm depth, screw and snap-on 35 mm DIN rail mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RH6140-1AR60 — Identification
ParameterValue
Contactor frame sizeS00
3RH6140-1AR60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.6 A
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V6 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH6140-1AR60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz400 V
3RH6140-1AR60 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH6140-1AR60 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail
3RH6140-1AR60 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH6140-1AR60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH6140-1AR60 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth73 mm
3RH6140-1AR60 — Specifications
ParameterValue
At AC10 000 1/h

Product details

What the 4 NO contacts actually buy you

The 3RH6140-1AR60 is a SIRIUS contactor relay with four normally-open auxiliary contacts, identified by the switching element code 40 E. That means you get four independent NO circuits in one 45 mm-wide package — no mixing NC and NO, just four make contacts for signal interlocking, PLC inputs, or pilot duty loads. The 6 kV rated surge voltage resistance means the contacts handle switching transients on inductive loads without welding shut prematurely.

Mounting and panel fit for the S00 frame

For AWG builds, that's 2x 20-16, 2x 18-14, or 2x 12. Finely stranded wire with core end processing uses the same cross-section ranges.

Coil draw and operating limits

AC coil with apparent pick-up power of 37 VA and holding power of 5.7 VA at 0.8 inductive power factor. The coil voltage tolerance is 0.8 to 1.1x rated at 50 Hz, 0.85 to 1.1x at 60 Hz — so a nominal 230 V coil stays pulled in down to about 184 V at 50 Hz.

MPN
3RH6140-1AR60