Siemens 3RH7140-1AV00 SIRIUS Contactor Relay, 4 NO

MPN3RH7140-1AV00

Siemens SIRIUS 3RH7140-1AV00 contactor relay, size S00, 4 NO auxiliary contacts, 6 A at 400 V AC, screw-type terminals, IP20 front, DIN-rail snap-on mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RH7140-1AV00 — Identification
ParameterValue
Contactor frame sizeS00
3RH7140-1AV00 — Ratings & Performance
ParameterValue
Rated value @ 400 V6 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RH7140-1AV00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz400 V
3RH7140-1AV00 — Contacts & Poles
ParameterValue
Auxiliary contact reliabilityacceptability for PLC control (17 V, 5 mA)
3RH7140-1AV00 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail
3RH7140-1AV00 — Environmental
ParameterValue
Operating temperature range-10 ... +55 °C
Storage temperature range-25 ... +70 °C
Installation altitude, max.2 000 m
3RH7140-1AV00 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

Active production — what that means for your BOM

The 3RH7140-1AV00 is a size S00 contactor relay with 4 NO auxiliary contacts (identification 40 E).

Panel fit and wiring — DIN-rail snap-on with screw terminals

Auxiliary and control circuits terminate with screw-type terminals. Finely stranded wire with core-end processing also fits the same ranges.

The AC coil draws 27 VA apparent power at pick-up and 5.4 VA holding, with inductive power factors of 0.8 and 0.27 respectively. The holding VA is low enough that a typical 24 V AC control transformer can run several of these relays without exceeding its rating — but the pick-up surge matters if you are energising multiple coils simultaneously. Auxiliary contacts are rated for PLC-level reliability: 17 V, 5 mA minimum switching capability. That means they can switch low-energy signals from a PLC input directly without needing an interposing relay — a detail that saves a component and a wiring step when the control voltage is 24 V DC.

Frequently asked questions

What is the rated switching current of 3RH7140-1AV00 at different voltages?

At 24 V, 230 V, and 400 V AC it is rated 6 A. At 110 V and 690 V AC it is rated 1 A. At 220 V AC it is rated 0.3 A. The 400 V rating is the headline figure for motor control circuits.

MPN
3RH7140-1AV00