Skip to main content
Siemens 3RK1105-1AG04-2CA0 — Remote I/O & Fieldbus Modules

Siemens 3RK1105-1AG04-2CA0 ASIsafe Safety Monitor, 1 Enablin

MPN3RK1105-1AG04-2CA0

Siemens SIRIUS ASIsafe extended safety monitor, 3RK1105-1AG04-2CA0, 1 enabling circuit, 1 F-RO safe output relay, 40 ms response, IP20, spring-loaded terminals, Cat 4 / PL e / SIL 3.

$558.80Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RK1105-1AG04-2CA0 — Identification
ParameterValue
Product designsafety monitor, with expanded functionality
3RK1105-1AG04-2CA0 — Communication
ParameterValue
AS-Interface supportYes
3RK1105-1AG04-2CA0 — Environmental
ParameterValue
Ingress protection (IP)IP20
Operating temperature range-20 ... +60°C
Storage temperature range-30 ... +70°C
3RK1105-1AG04-2CA0 — Mechanical
ParameterValue
Width45mm
Depth120mm
Height108mm
Mounting methodscrews / DIN rail

Product details

ASIsafe extended safety monitor — 1 enabling circuit, 1 F-RO

The Siemens 3RK1105-1AG04-2CA0 is an ASIsafe extended safety monitor with one enabling circuit and one fail-safe relay output (F-RO). It is designed to guard hazardous zones on automated machinery, providing a monitored path for the enabling switch that an operator must hold to allow motion. The safe output relay is rated for DC-12 (DC-1) at 24 V at 3 A and AC-12 at 250 V at 3 A, so it can switch both DC and AC loads in the safety circuit. The unit's maximum response time is 40 ms, which sets the window for the safety function to react to an opening guard or released enabling switch. This monitor is rated for use up to Category 4 per EN 954-1, Performance Level e per EN ISO 13849-1, and SIL 3 per IEC 61508. Those ratings mean it is suitable for high-risk safety functions where a single fault cannot lead to loss of the safety function, and where redundant, monitored architecture is required. The 40 ms response time is the maximum interval from the input condition change to the output relay opening — critical for calculating the stopping distance of guarded equipment.

The 45 mm width fits a standard modular enclosure slot. Connections use spring-loaded terminals on removable plugs — strip length per the manufacturer's recommendation for spring-cage terminations. The monitor communicates over the AS-Interface protocol, integrating into an ASIsafe network where the safety-related inputs (E-stop, guard switches, enabling switches) are carried on the yellow AS-i cable alongside standard I/O. The spring-loaded terminals on the monitor handle the safe output wiring separately from the AS-i bus connection.

Frequently asked questions

Where can I buy 3RK1105-1AG04-2CA0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the 24 V rating on this safety monitor?

The safe output relay is rated for DC-12 (DC-1) at 24 V at 3 A, meaning it can switch a 24 VDC load up to 3 A in the safety circuit. The 24 V control supply draw is listed at 1 A.

What safety integrity levels does this monitor support?

It is rated for Category 4 per EN 954-1, Performance Level e per EN ISO 13849-1, and SIL 3 per IEC 61508.

What is the response time of the 3RK1105-1AG04-2CA0?

The maximum response time is 40 ms from the input condition change to the safe output relay opening.

MPN
3RK1105-1AG04-2CA0