Skip to main content
Siemens 3RK1105-1BG04-2CA0 — Remote I/O & Fieldbus Modules

Siemens 3RK1105-1BG04-2CA0 ASIsafe Safety Monitor, 2 F-RO, I

MPN3RK1105-1BG04-2CA0

Siemens ASIsafe extended Safety monitor, 2 F-RO, 2 enabling circuits, IP20, spring-type terminals, 40ms response time, up to Category 4 / PL e / SIL 3.

$741.68Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RK1105-1BG04-2CA0 — Identification
ParameterValue
Product designsafety monitor, with expanded functionality
3RK1105-1BG04-2CA0 — Communication
ParameterValue
AS-Interface supportYes
3RK1105-1BG04-2CA0 — Environmental
ParameterValue
Ingress protection (IP)IP20
Operating temperature range-20 ... +60°C
Storage temperature range-30 ... +70°C
3RK1105-1BG04-2CA0 — Mechanical
ParameterValue
Width45mm
Depth120mm
Height108mm
Mounting methodscrews / DIN rail

Product details

Safety monitor for AS-Interface safety networks

The Siemens 3RK1105-1BG04-2CA0 is an ASIsafe extended safety monitor with expanded functionality, designed to supervise safety circuits on an AS-Interface network. It provides 2 enabling circuits (2 F-RO outputs) and achieves a maximum response time of 40 ms, making it suitable for guarding applications where fast reaction to a safety demand is required. Rated for use up to Category 4 per EN 954-1, Performance Level e per EN ISO 13849-1, and SIL 3 per IEC 61508, this monitor integrates into safety-rated control systems for machinery guarding, press lines, and automated assembly cells where a safety-rated stop is required within the AS-Interface loop.

The 24 V control supply draws 1 A — this is the current the monitor pulls from the AS-Interface power supply or an auxiliary 24 VDC source. For a field-service tech isolating a fault: if the 24 V rail is sagging, this monitor's draw is a known load to account for. The 115 V and 230 V ratings (0.1 A and 0.05 A respectively) are for the enabling circuit outputs — these are the contact ratings for switching loads at those voltages. The DC-12 (DC-1) 24 V rating of 3 A and the AC-12 250 V rating of 3 A define the maximum continuous current the safety outputs can carry under resistive loads. For a controls integrator: if your enabling circuit drives a contactor coil or a pilot light, stay within these limits. The 40 ms response time is the maximum delay from a safety input demand to the outputs opening — critical for stopping distance calculations in safeguarding applications.

IP20 rated, so it belongs in a clean, dry control cabinet — not on the machine frame in a washdown zone. I/O connections use spring-loaded terminals — no screwdriver needed for wiring, which speeds panel assembly and reduces loose-connection callbacks. The reference code per EN 61346-2 is F, meaning it's classified as a protective device in the system documentation.

Frequently asked questions

What are the key ratings for this safety monitor?

24 V control supply draws 1 A. Safety outputs rated DC-12 24 V 3 A and AC-12 250 V 3 A. Maximum response time is 40 ms. Supports up to Category 4 / PL e / SIL 3.

What type of terminals does it use?

Spring-loaded terminals for all I/O connections. No screwdriver required; strip length per manufacturer spec for the wire gauge used.

MPN
3RK1105-1BG04-2CA0