Skip to main content
Siemens 3RK1200-0CE03-0AA2 — Remote I/O & Fieldbus Modules

Siemens 3RK1200-0CE03-0AA2 AS-Interface Counter Module, 1 DI

MPN3RK1200-0CE03-0AA2
Active

Siemens SIRIUS 3RK1200-0CE03-0AA2 AS-Interface counter module, 1 DI counter input, 22.5 mm width, IP20, screw-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RK1200-0CE03-0AA2 — Identification
ParameterValue
Product designcounter modules - modules with special functions
3RK1200-0CE03-0AA2 — Communication
ParameterValue
AS-Interface supportNo
3RK1200-0CE03-0AA2 — Environmental
ParameterValue
Ingress protection (IP)IP20
Operating temperature range-25 ... +70°C
Storage temperature range-40 ... +85°C
3RK1200-0CE03-0AA2 — Mechanical
ParameterValue
Width22.5mm
Depth86mm
Height102mm
Mounting methodstandard rail mounting/wall mounting

Product details

The Siemens 3RK1200-0CE03-0AA2 is an AS-Interface counter module from the SIRIUS family, designed as a standard slave with ID code F. It provides one digital counter input (PNP) in a 22.5 mm wide housing, making it a compact addition to an AS-i bus segment for counting pulses from sensors, encoders, or limit switches on a conveyor or machine cycle.

The module measures 22.5 mm wide by 102 mm high by 86 mm deep, fitting a standard 35 mm DIN rail per EN 50022 or wall-mounting via the integral lugs. At 22.5 mm, it occupies one single-width slot — useful when panel density is tight and you need to add a counter without expanding the enclosure. The screw-type terminals accept field wiring directly — no special tooling needed for the sensor and AS-i connections.

Electrical interface and diagnostics

The AS-Interface bus supplies both power and data. Operating voltage per the AS-i specification is 26.5... 31.6 V; the module draws up to 170 mA from the bus total current. The sensor supply for the input is short-circuit and overload resistant, rated at 90 mA at 40 °C ambient — enough for a standard inductive proximity or photoelectric sensor. Input voltage range is 20... 30 V, with a switching threshold: low max 5 V, high min 10 V. Signal current at state 1 minimum is 10 mA; at state 0 maximum is 2 mA. The input is PNP. Pin assignment: terminal 7 = +, terminal 9 = -, terminal 8 = IN1. Status indication uses a bicolor LED on the AS-Interface: green on + red off = normal operation; green off + red on = no data traffic; green flashing + red on = zero address; green off + red flashing = sensor overload. This lets a field tech diagnose a missing slave or a shorted sensor without a bus monitor.

Environmental limits

The operating range covers most indoor industrial enclosures; the storage range accommodates warehouse extremes without issue.

Frequently asked questions

Where can I buy 3RK1200-0CE03-0AA2 and get a price?

This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing.

What is the width and depth of this module?

Width is 22.5 mm, depth is 86 mm, height is 102 mm.

What does the AS-Interface status LED indicate?

Green LED on and red off means normal operation; green off and red on means no data traffic; green flashing with red on means zero address; green off with red flashing means sensor overload.

What is the sensor supply current available?

The sensor supply is rated at 90 mA at 40 °C ambient, short-circuit and overload resistant.

MPN
3RK1200-0CE03-0AA2