Siemens 3RK1300-0CS01-0AA1 — Remote I/O & Fieldbus Modules

Siemens 3RK1300-0CS01-0AA1 Direct Starter, 0.18–0.25 A, IP65

MPN3RK1300-0CS01-0AA1

Siemens SIRIUS 3RK1300-0CS01-0AA1, electromechanical direct starter, setting range 0.18–0.25 A, 0.06 kW at 400 V AC-3, IP65, PROFIBUS DP, with brake output.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RK1300-0CS01-0AA1 — Identification
ParameterValue
Product designdirect starter
3RK1300-0CS01-0AA1 — Communication
ParameterValue
PROFIBUS DP supportYes
AS-Interface supportNo
Bus communicationYes
3RK1300-0CS01-0AA1 — Electrical
ParameterValue
Voltage typeDC
Operating Voltage Rated Value400 ... 500V
3RK1300-0CS01-0AA1 — Environmental
ParameterValue
Ingress protection (IP)IP65
Ambient operating temperature0 ... 55°C
3RK1300-0CS01-0AA1 — Mechanical
ParameterValue
Width140mm
Depth134mm
Height270mm
3RK1300-0CS01-0AA1 — Specifications
ParameterValue
At AC-3 at 400 V rated value0.06kW
Type Of The Motor Protectionbimetal

Product details

The Siemens 3RK1300-0CS01-0AA1 is an EM 300 DS electromechanical direct starter from the SIRIUS family, designed for the ET 200X distributed I/O system. It integrates motor starting, bimetal overload protection, and short-circuit protection via circuit-breakers into a single IP65-rated enclosure, making it suited for on-machine mounting in washdown environments. The setting range covers 0.18 A initial to 0.25 A full-scale, corresponding to a motor rating of 0.06 kW at 400 V AC-3 duty. That AC-3 rating means it's sized for starting squirrel-cage induction motors under load — the typical case for conveyors, pumps, and small fans on a distributed line. Operating voltage is 400–500 V, and the maximum short-circuit current breaking capacity (Icu) at 400 V is 50 A, which governs the upstream protection coordination. The unit includes a motor brake output rated DC 24 V/3 A for externally supplied brakes, and communicates via PROFIBUS DP.

Deployment context

The dimensions (134 mm deep, 140 mm wide, 270 mm high) and tab-terminal main circuit connections are designed for the ET 200X mounting rail system, not a standard DIN rail. Ambient operating temperature is 0 to 55 °C, which covers most conditioned and unconditioned plant-floor environments but not freezer or outdoor desert applications without derating. The equipment marking per DIN EN 61346-2 is Q, identifying it as a switching device in the schematic.

Frequently asked questions

Where can I buy 3RK1300-0CS01-0AA1 and get a price?

This part is sourced to order against a request for quotation. Submit an RFQ with your quantity and target delivery window; we confirm availability and current pricing at quote time through our supply network.

What is the setting range and motor rating for 3RK1300-0CS01-0AA1?

The setting range is 0.18 A initial to 0.25 A full-scale, corresponding to a motor rating of 0.06 kW at 400 V AC-3. The operating voltage is 400–500 V.

Does 3RK1300-0CS01-0AA1 include a brake output?

Yes, it includes a motor brake output component rated DC 24 V/3 A for externally supplied brakes, integrated into the 9-pole motor feeder and power connection.

What communication protocol does this direct starter support?

It supports PROFIBUS DP for bus communication. AS-interface is not available on this variant.

What is the short-circuit breaking capacity of 3RK1300-0CS01-0AA1?

The maximum short-circuit current breaking capacity (Icu) at 400 V is 50 A. Short-circuit protection is designed for use with circuit-breakers.

MPN
3RK1300-0CS01-0AA1