Skip to main content
Siemens 3RK1301-0BB00-0AA2 — Remote I/O & Fieldbus Modules

Siemens 3RK1301-0BB00-0AA2 SIMATIC Motor Starter, CLASS 10,

MPN3RK1301-0BB00-0AA2

Siemens SIMATIC motor starter, order code 3RK1301-0BB00-0AA2, direct starter design, CLASS 10 trip, 50 kA at 400 V, PROFINET and PROFIBUS DP, 24 V DC control.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RK1301-0BB00-0AA2 — Identification
ParameterValue
Product designationMotor starters
Product designdirect starter
3RK1301-0BB00-0AA2 — Communication
ParameterValue
PROFIBUS DP supportYes
PROFINET supportYes
AS-Interface supportNo
Bus communicationYes
3RK1301-0BB00-0AA2 — I/O
ParameterValue
Digital inputs0
Digital input signals0
Digital output signals0
Digital inputs parameterizableNo
Digital outputs parameterizableNo
3RK1301-0BB00-0AA2 — Electrical
ParameterValue
Rated value (DC)20.4 ... 28.8 V
Control supply voltage typeDC
Rated surge voltage6 kV
Adjustable Current Response Value Current Of The Current-Dependent Overload Release0.14 ... 0.2 A
Operating Voltage Rated Value200 ... 400 V
Number Of Poles For Main Current Circuit3
3RK1301-0BB00-0AA2 — Environmental
ParameterValue
Operating temperature range0 ... 60 °C
Storage temperature range-40 ... +70 °C
Shock resistance5g / 11 ms
Pollution degree3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)
3RK1301-0BB00-0AA2 — Mechanical
ParameterValue
Width45 mm
Depth120 mm
Height265 mm
Mounting methodpluggable on terminal module
3RK1301-0BB00-0AA2 — Specifications
ParameterValue
At 400 V rated value50 kA
At AC-3 at 400 V rated value0.2 A
Reverse StartingNo
Type Of The Motor Protectionbimetal
Trip ClassCLASS 10

Product details

The Siemens 3RK1301-0BB00-0AA2 is a SIMATIC-branded direct motor starter — a compact, integrated unit that combines a contactor, overload relay, and short-circuit protection into one device for controlling a single three-phase motor in a direct-on-line (DOL) start configuration. Communication is built in: the starter supports both PROFINET and PROFIBUS DP protocols, so it drops directly into a Siemens automation network without an extra gateway module.

Mounting, wiring, and panel fit

The starter measures 45 mm wide by 265 mm tall by 120 mm deep — a 45 mm footprint on the DIN rail, which is a standard width for a motor starter of this class. The 120 mm depth means it will sit proud of the backplane, so check enclosure depth clearance before laying out the panel. It fastens by plugging onto a terminal module — the power and control wiring lands on a base unit, and the starter module clips onto it. This means you can pre-wire the panel and snap the starter in later, or swap a failed starter without disturbing the wiring. The main energy infeed uses screw-type terminals, so expect to torque down ring or fork lugs on the power connections — no spring-cage on the main feed. Mounting position is flexible: vertical or horizontal orientation is permitted, which helps when laying out dense panels where rail space is tight.

Control voltage and environmental limits

The control circuit is 24 V DC nominal, with a permissible range of 20.4 to 28.8 V DC — standard for industrial 24 V supplies. The maximum permissible voltage is 28.8 V, so do not exceed that even on a float-charged battery backup. The unit is rated for vibration resistance of 2g and shock resistance of 5g / 11 ms — robust enough for machine-mounted applications near rotating equipment. Pollution degree rating is 3 at 400 V and 2 at 500 V per IEC 60664 / IEC 61131 — pollution degree 3 means the environment is industrial with conductive or dry non-conductive pollution, which is the standard assumption for most control panels not in a clean room.

No successor has been announced, and no cross-reference to a different series is needed — this is the part to specify.

Frequently asked questions

What are the key ratings that decide fit for my motor?

The trip class is CLASS 10, which matches standard induction motor starting profiles. The short-circuit breaking capacity is 50 kA at 400 V — sufficient for most industrial panels with high fault current. The control voltage is 24 V DC, range 20.4 to 28.8 V. Communication is PROFINET and PROFIBUS DP.

What are the physical dimensions for panel layout?

Width is 45 mm, height is 265 mm, depth is 120 mm. It mounts on a DIN rail via a pluggable terminal module, and can be oriented vertically or horizontally.

Does this starter include a bypass circuit?

Yes, the power dissipation with the bypass circuit engaged is listed as 4.1184 W, and without bypass it is 4.118 W — the bypass is present and reduces power loss in the running state.

MPN
3RK1301-0BB00-0AA2