Skip to main content
Siemens 3RK1304-5LS40-3AA3 — Remote I/O & Fieldbus Modules

Siemens 3RK1304-5LS40-3AA3 SIMATIC Motor Starter, IP65

MPN3RK1304-5LS40-3AA3
Active

Siemens SIMATIC 3RK1304-5LS40-3AA3 reversing motor starter, IP65, 12 A at 400 V AC, CLASS 10, PROFINET and PROFIBUS DP, 4 digital inputs, 150 x 110 x 230 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RK1304-5LS40-3AA3 — Identification
ParameterValue
Product designationMotor starters
Product designreversing starter
3RK1304-5LS40-3AA3 — Communication
ParameterValue
PROFIBUS DP supportYes
PROFINET supportYes
AS-Interface supportNo
Bus communicationYes
3RK1304-5LS40-3AA3 — I/O
ParameterValue
Digital inputs4
Digital input signals4
Digital output signals0
Digital inputs parameterizableYes
Digital outputs parameterizableNo
3RK1304-5LS40-3AA3 — Electrical
ParameterValue
Rated value (DC)20.4 ... 28.8 V
Control supply voltage typeDC
Rated surge voltage6 kV
Voltage typeAC
Adjustable Current Response Value Current Of The Current-Dependent Overload Release1.5 ... 12 A
Operating Voltage Rated Value200 ... 400 V
Number Of Poles For Main Current Circuit3
3RK1304-5LS40-3AA3 — Environmental
ParameterValue
Ingress protection (IP)IP65
Operating temperature range-25 ... +55 °C
Storage temperature range-40 ... +70 °C
Shock resistance15g / 11 ms
Pollution degree3
3RK1304-5LS40-3AA3 — Mechanical
ParameterValue
Width110 mm
Depth150 mm
Height230 mm
Mounting methodscrew fixing
3RK1304-5LS40-3AA3 — Specifications
ParameterValue
At 400 V rated value100 000 A
At AC-3 at 400 V rated value5 500 W
Reverse StartingYes
Type Of The Motor Protectionsolid-state
Trip ClassCLASS 10

Product details

IP65 reversing motor starter with dual-fieldbus connectivity

The 3RK1304-5LS40-3AA3: This SIMATIC motor starter is a reversing starter — it handles forward and reverse motor direction control directly, without external contactor interlocking. The IP65 enclosure means it mounts directly on the machine frame in washdown zones, not inside a separate control panel. It supports both PROFINET and PROFIBUS DP protocols natively, so it drops into either fieldbus architecture without an additional gateway. The 4 digital inputs (M12 socket) and 2-byte input/output process data map directly into the controller's I/O image.

Rated for motor protection and fault interruption

The breaking capacity of 100,000 A at 400 V ensures it can interrupt high-fault-current events without upstream damage. Supply voltage range is 20.4 to 28.8 V DC (nominal 24 V DC), with the control logic powered from the same rail. Power dissipation is 3.888 W both with and without the bypass circuit engaged, so thermal management in the enclosure is consistent regardless of operating state.

Physical fit and environmental ratings

Dimensions are 150 mm deep, 110 mm wide, 230 mm high — this is a compact footprint for a reversing starter with integrated fieldbus. Rated IP65, with degree of pollution 3 (conductive pollution typical in industrial environments). Vibration resistance is 2g, shock resistance 15g for 11 ms — this holds up on moving machine axes or near press equipment.

Frequently asked questions

What fieldbus protocols does this motor starter support?

It supports both PROFINET and PROFIBUS DP protocols, allowing direct integration into either fieldbus architecture without additional gateways or couplers.

What is the physical size and mounting method?

Dimensions are 150 mm depth, 110 mm width, 230 mm height. Mounting is by screw fixing, and the unit can be installed in either vertical or horizontal orientation.

MPN
3RK1304-5LS40-3AA3