Skip to main content
Siemens 3RK1308-0AD00-0CP0 — Remote I/O & Fieldbus Modules

Siemens 3RK1308-0AD00-0CP0 SIMATIC Direct-On-Line Starter, 9

MPN3RK1308-0AD00-0CP0
Active

Siemens SIMATIC direct-on-line starter, 3RK1308-0AD00-0CP0, 9 A at 40 °C, 55 kA SCCR at 400/500 V, PROFINET and PROFIBUS protocol, adjustable trip class OFF/5/10.

$99.38Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RK1308-0AD00-0CP0 — Identification
ParameterValue
Product designationDirect-on-line starter
3RK1308-0AD00-0CP0 — Communication
ParameterValue
PROFIBUS DP supportYes
PROFINET supportYes
AS-Interface supportNo
Bus communicationYes
3RK1308-0AD00-0CP0 — I/O
ParameterValue
Digital inputs4
3RK1308-0AD00-0CP0 — Electrical
ParameterValue
Rated surge voltage6 kV
Adjustable Current Response Value Current Of The Current-Dependent Overload Release2.8 ... 9 A
Operating Voltage Rated Value48 ... 500 V
Number Of Poles For Main Current Circuit3
3RK1308-0AD00-0CP0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; For derating see manual
Storage temperature range-40 ... +70 °C
Shock resistance6g / 11 ms
Pollution degree2
3RK1308-0AD00-0CP0 — Mechanical
ParameterValue
Width30 mm
Depth150 mm
Height142 mm
Mounting methodpluggable in BaseUnit
3RK1308-0AD00-0CP0 — Specifications
ParameterValue
At 400 V rated value55 kA
Reverse StartingNo
Type Of The Motor Protectionsolid-state
Trip ClassCLASS OFF / 5 / 10 adjustable

Product details

The Siemens 3RK1308-0AD00-0CP0 is a SIMATIC-branded direct-on-line motor starter — a compact, fieldbus-capable unit that combines a contactor, overload relay, and communication interface in a single 30 mm-wide housing that plugs into a base unit. It is rated for 9 A at 40 °C, with a short-circuit current rating of 55 kA at both 400 V and 500 V — meaning it can safely interrupt fault currents up to that level without upstream devices needing to clear the fault first. The trip class is adjustable between OFF, 5, and 10, which lets you match the thermal curve to the motor's starting profile — set to OFF for applications where the overload is handled externally, or to 5 or 10 for standard motor protection. It supports both PROFINET and PROFIBUS DP protocols, so it drops into either a PN or a legacy DP network without a gateway.

The module fastens by plugging into a base unit on the DIN rail — no separate wiring for the power bus; the base unit carries the line and load connections. Dimensions are 30 mm wide, 142 mm high, and 150 mm deep, with 50 mm clearance required above and below for ventilation and cable routing. Mounting position is vertical or horizontal, but per the manual derating applies for horizontal orientation — factor that into your thermal budget if the panel layout forces a horizontal mount. Operating temperature range is -25 to +60 °C, with derating required above 40 °C; storage and transport range extends to -40 to +70 °C.

The listed MTBF of 46 a gives a mean time between failures of 46 years under stated operating conditions — a reliability figure that supports long service intervals in continuous-duty applications.

The minimum load is 50 % of the smallest adjustable rated current — meaning the overload protection may not trip reliably below that threshold, so don't use this on a motor drawing less than half the set current. ON-delay time is fixed at 20 ms; OFF-delay is adjustable between 35 and 50 ms — these govern the response to start/stop commands from the fieldbus or local control. Vibration resistance is 15 mm at 6 Hz and 2 g up to 500 Hz; shock resistance is 6 g for 11 ms — suitable for mounting on machinery that sees moderate vibration, but not for high-shock environments like stamping presses without additional isolation.

Frequently asked questions

What is the MTBF of 3RK1308-0AD00-0CP0?

The listed MTBF is 46 a (46 years) under specified operating conditions, which supports long maintenance intervals in continuous-duty applications.

What does the '4 via 3DI/LC module' note mean?

It indicates this module provides 4 digital inputs and a load circuit (LC) interface via the 3DI/LC module designation — the unit integrates local I/O for start/stop and feedback signals without a separate I/O block.

MPN
3RK1308-0AD00-0CP0