Skip to main content
Siemens 3RK1315-6LS41-1AA0 — Remote I/O & Fieldbus Modules

Siemens 3RK1315-6LS41-1AA0 SIRIUS Reversing Starter, 5.5 kW

MPN3RK1315-6LS41-1AA0
NRND

Siemens SIRIUS reversing motor starter, 3RK1315-6LS41-1AA0, 5.5 kW at 400 V, CLASS 10, IP65, AS-Interface, 24 VDC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RK1315-6LS41-1AA0 — Identification
ParameterValue
Product designationMotor starters
Product designreversing starter
3RK1315-6LS41-1AA0 — Communication
ParameterValue
PROFIBUS DP supportNo
PROFINET supportNo
AS-Interface supportYes
AS-Interface supportYes
Bus communicationYes
3RK1315-6LS41-1AA0 — I/O
ParameterValue
Digital inputs4
Digital input signals4
Digital output signals1
Digital inputs parameterizableNo
Digital outputs parameterizableNo
3RK1315-6LS41-1AA0 — Electrical
ParameterValue
Rated value (DC)20.4 ... 28.8 V
Control supply voltage typeDC
Rated surge voltage6 000 V
Adjustable Current Response Value Current Of The Current-Dependent Overload Release1.5 ... 12 A
Operating Voltage Rated Value200 ... 440 V
Number Of Poles For Main Current Circuit3
3RK1315-6LS41-1AA0 — Environmental
ParameterValue
Ingress protection (IP)IP65
Operating temperature range-25 ... +55 °C
Storage temperature range-40 ... +70 °C
Shock resistance12g / 11 ms
Pollution degree3
3RK1315-6LS41-1AA0 — Mechanical
ParameterValue
Width294 mm
Depth159 mm
Height215 mm
Mounting methodscrew fixing
3RK1315-6LS41-1AA0 — Specifications
ParameterValue
At 400 V rated value5.5 kW
At AC-3 at 400 V rated value12 A
Reverse StartingYes
Type Of The Motor Protectionfull motor protection
Trip ClassCLASS 10

Product details

It is rated for 5.5 kW at 400 V (7.5 hp at 460/480 V, 10 hp at 575/600 V) and carries a CLASS 10 trip curve, meaning it will trip within 10 seconds at 7.2× the set current — standard for protecting standard induction motors during stall or jam conditions. It communicates via AS-Interface (the only fieldbus protocol on board; no PROFIBUS or PROFINET), with device addressing through an M12 plug. The main circuit connects via a HAN Q4/2 plug per ISO 23570, and it includes 4 digital inputs for local control signals.

Mounts via screw fixing in any orientation — vertical, horizontal, or flat — though horizontal is recommended for optimal thermal performance. Dimensions are 294 mm wide, 215 mm high, and 159 mm deep. The supply voltage is 24 VDC nominal (20.4 to 28.8 V range, maximum permissible 31.6 V). Shock resistance is 12g for 11 ms, vibration resistance is 7 mm / 2g — robust enough for most industrial machinery, including conveyors and pumps.

Frequently asked questions

What are the key ratings for this reversing starter?

Rated 5.5 kW at 400 V (7.5 hp at 460/480 V, 10 hp at 575/600 V), CLASS 10 trip curve, IP65 enclosure, 24 VDC supply, AS-Interface communication, 4 digital inputs.

What environmental ratings does it carry?

IP65 protection, operating temperature -25 to +55 °C, storage/transport -40 to +70 °C, shock 12g / 11 ms, vibration 7 mm / 2g.

MPN