Skip to main content
Siemens 3RK1315-6LS41-1AA5 — Remote I/O & Fieldbus Modules

Siemens 3RK1315-6LS41-1AA5 SIRIUS Reversing Starter, IP65, 5

MPN3RK1315-6LS41-1AA5
NRND

Siemens SIRIUS reversing motor starter, 3RK1315-6LS41-1AA5, IP65, Class 10, 5.5 kW at 400 V, AS-Interface, 24 V DC, 159 x 294 x 215 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RK1315-6LS41-1AA5 — Identification
ParameterValue
Product designationMotor starters
Product designreversing starter
3RK1315-6LS41-1AA5 — Communication
ParameterValue
PROFIBUS DP supportNo
PROFINET supportNo
AS-Interface supportYes
AS-Interface supportYes
Bus communicationYes
3RK1315-6LS41-1AA5 — I/O
ParameterValue
Digital inputs4
Digital input signals4
Digital output signals1
Digital inputs parameterizableNo
Digital outputs parameterizableNo
3RK1315-6LS41-1AA5 — Electrical
ParameterValue
Rated value (DC)20.4 ... 28.8 V
Control supply voltage typeDC
Rated surge voltage6 000 V
Adjustable Current Response Value Current Of The Current-Dependent Overload Release1.5 ... 12 A
Operating Voltage Rated Value200 ... 440 V
Number Of Poles For Main Current Circuit3
3RK1315-6LS41-1AA5 — Environmental
ParameterValue
Ingress protection (IP)IP65
Operating temperature range-25 ... +55 °C
Storage temperature range-40 ... +70 °C
Shock resistance12g / 11 ms
Pollution degree3
3RK1315-6LS41-1AA5 — Mechanical
ParameterValue
Width294 mm
Depth159 mm
Height215 mm
Mounting methodscrew fixing
3RK1315-6LS41-1AA5 — Specifications
ParameterValue
At 400 V rated value5.5 kW
At AC-3 at 400 V rated value12 A
Reverse StartingYes
Type Of The Motor Protectionfull motor protection
Trip ClassCLASS 10

Product details

It's designed for direct-on-line reversing of three-phase motors up to 5.5 kW at 400 V (7.5 hp at 460/480 V, 10 hp at 575/600 V), with a Trip Class 10 overload curve that protects standard induction motors during start-up.

AS-Interface integration and control voltage

This starter communicates over AS-Interface (the protocol is confirmed,), with device addressing via an M12 plug. The control supply is 24 V DC nominal, with a permissible range of 20.4 to 28.8 V DC. It includes 4 digital inputs for local pushbuttons or limit switches. The main power connection uses a HAN Q4/2 plug per ISO 23570, so panel builders should plan for that connector footprint rather than hardwiring directly.

Mounting is via screw fixing in any orientation — vertical, horizontal, or flat. The recommended mounting position is horizontal. Shock resistance is 12g for 11 ms, and vibration resistance is 7 mm / 2g. These ratings make it suitable for machine-mounted applications with moderate vibration, such as conveyors or small hoists.

Frequently asked questions

What is the closest functional second-source to 3RK1315-6LS41-1AA5?

The peer MPNs listed (3RT5065-6NF36, 3RT1044-1FB46, 3RT5065-6AB36) are standard contactors, not reversing starters with integrated overload and AS-Interface. They are not drop-in replacements; the 3RK1315-6LS41-1AA5 is a dedicated reversing starter with built-in control logic and IP65 enclosure, so a substitution would require rewiring and a separate enclosure.

Where can I buy 3RK1315-6LS41-1AA5 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

MPN
3RK1315-6LS41-1AA5