Skip to main content
Siemens 3RK1322-0HS02-1AA4 — Remote I/O & Fieldbus Modules

Siemens 3RK1322-0HS02-1AA4 AS-i Compact Reversing Starter, 0

MPN3RK1322-0HS02-1AA4

Siemens SIRIUS AS-i compact reversing starter, electromechanical, setting range 0.55–0.8 A, AC-3 0.21 kW / 400 V, IP65, with brake contact and 9-pole motor/power connections.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RK1322-0HS02-1AA4 — Identification
ParameterValue
Product designreversing starter
3RK1322-0HS02-1AA4 — Communication
ParameterValue
PROFIBUS DP supportNo
AS-Interface supportYes
Bus communicationYes
3RK1322-0HS02-1AA4 — Electrical
ParameterValue
Voltage typeDC
3RK1322-0HS02-1AA4 — Environmental
ParameterValue
Ingress protection (IP)IP65
Ambient operating temperature-25 ... +55 °C
3RK1322-0HS02-1AA4 — Mechanical
ParameterValue
Width120 mm
Depth190 mm
Height270 mm
3RK1322-0HS02-1AA4 — Specifications
ParameterValue
Type Of The Motor Protectionbimetal

Product details

The Siemens 3RK1322-0HS02-1AA4 is an AS-i compact reversing starter from the SIRIUS family — a self-contained motor starting and reversing unit rated for 0.55–0.8 A (initial to full-scale) and 0.21 kW at AC-3 duty on a 400 V line. It's an electromechanical reversing starter with bimetal motor protection and circuit-breaker-based short-circuit protection, all housed in an IP65 enclosure that handles washdown environments. Communication is via AS-interface protocol (not PROFIBUS DP), with two integrated inputs and a motor brake output (500 V DC / 1 A) built in. The main current circuit connects through tab terminals, typical for quick field wiring in distributed motor starter applications.

The 0.55–0.8 A setting range covers small reversing motor loads — think fractional-horsepower conveyors, diverters, or valve actuators. The AC-3 rating at 400 V (0.21 kW) is the motor-switching duty: it's the current the contacts handle during starting and plugging, not the resistive-heating rating. For a 0.21 kW motor at 400 V three-phase, full-load current sits around 0.5–0.6 A, so this starter is sized correctly for that specific motor frame. In a panel with a high-available-fault-current bus (common in industrial distribution), this rating means you don't need an upstream current-limiting fuse to protect the starter itself.

For a BOM line that calls out 3RK1322-0HS02-1AA4, the fit is confirmed by the setting range (0.55–0.8 A), the reversing function, the AS-i bus interface, and the IP65 enclosure. The tab-terminal main connections and 9-pole motor/power connectors are specific to this variant — verify the connector pattern matches your existing harness before committing the order.

Frequently asked questions

What are the key ratings for this reversing starter?

Setting range 0.55–0.8 A, AC-3 rated power 0.21 kW at 400 V, short-circuit breaking capacity 50 kA at 400 V, IP65 enclosure, operating temperature -25 to +55 °C.

What communication protocol does this starter use?

It uses AS-interface protocol. It does not support PROFIBUS DP.

Does this part include a motor brake output?

Yes, it has a built-in motor brake output rated for 500 V DC / 1 A.

MPN
3RK1322-0HS02-1AA4