Skip to main content
Siemens 3RK1322-1BS02-0AA0 — Remote I/O & Fieldbus Modules

Siemens 3RK1322-1BS02-0AA0 direct starter, IP65, 2 A AC-3

MPN3RK1322-1BS02-0AA0

Siemens 3RK1322-1BS02-0AA0, direct starter, IP65, 2 A at AC-3 400 V, 400-500 V operating voltage, 50 kA short-circuit breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RK1322-1BS02-0AA0 — Identification
ParameterValue
Product designdirect starter
3RK1322-1BS02-0AA0 — Communication
ParameterValue
PROFIBUS DP supportNo
PROFINET supportNo
AS-Interface supportYes
3RK1322-1BS02-0AA0 — I/O
ParameterValue
Digital inputs2
Digital input signals1
Digital output signals0
Digital inputs parameterizableNo
Digital outputs parameterizableNo
3RK1322-1BS02-0AA0 — Electrical
ParameterValue
Rated value (DC)20.4 ... 28.8 V
Control supply voltage typeDC
Voltage typeDC
Operating Voltage Rated Value400 ... 500 V
Number Of Poles For Main Current Circuit3
3RK1322-1BS02-0AA0 — Environmental
ParameterValue
Ingress protection (IP)IP65
3RK1322-1BS02-0AA0 — Mechanical
ParameterValue
Width120 mm
Depth190 mm
Height270 mm
3RK1322-1BS02-0AA0 — Specifications
ParameterValue
At 400 V rated value50 000 A
At AC-3 at 400 V rated value2 A
Type Of The Motor Protectionbimetal

Product details

The Siemens 3RK1322-1BS02-0AA0 is a direct starter — a self-contained motor-starting and protection unit — built for AS-Interface networks. The enclosure is rated IP65, so the body and all connections are sealed against cement dust, airborne grit, and hose-down cleaning. That's the difference between a starter that eats the dust and runs versus one that chokes on it after a shift. Operating voltage range is 400 to 500 V AC, with a short-circuit breaking capacity of 50 kA at 400 V.

Integration and connectivity

Communication and power supply both run through AS-Interface shaped cables using cutting/clamping method — no separate fieldbus wiring looms. The unit has a front addressing socket for setting the AS-i address, and a socket according to ISO23570 handles the main energy infeed and load-side outgoing feeder. Two digital inputs are available via M12 sockets, parameterized as fixed (not configurable). There are no digital outputs on this variant. The design uses electromechanical switching contacts with bimetal motor protection. Dimensions are 270 mm high, 120 mm wide, 190 mm deep — fits a standard enclosure footprint. The IP65 rating means it can be mounted directly on the machine frame, not buried in a central cabinet, saving panel space and copper.

Frequently asked questions

What are the key ratings for this direct starter?

It is rated 2 A at AC-3 duty at 400 V, with an operating voltage range of 400 to 500 V AC. Short-circuit breaking capacity is 50 kA at 400 V. The enclosure is IP65.

How is this unit connected to the network and power?

Both AS-Interface communication and supply voltage connect via AS-I shaped cables using the cutting/clamping method. The main energy infeed and load-side feeder use sockets per ISO23570. A front addressing socket sets the AS-i address.

What are the physical dimensions?

Height is 270 mm, width 120 mm, depth 190 mm.

MPN
3RK1322-1BS02-0AA0