Skip to main content
Siemens 3RK1322-1CS02-0AA4 — Remote I/O & Fieldbus Modules

Siemens 3RK1322-1CS02-0AA4 AS-i Compact Starter, 1.8-2.5 A,

MPN3RK1322-1CS02-0AA4

Siemens SIRIUS 3RK1322-1CS02-0AA4, AS-Interface compact direct starter, electromechanical, setting range 1.8…2.5 A, AC-3 0.9 kW / 400 V, IP65, with integrated brake contact and 2 inputs.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RK1322-1CS02-0AA4 — Identification
ParameterValue
Product designdirect starter
3RK1322-1CS02-0AA4 — Communication
ParameterValue
PROFIBUS DP supportNo
AS-Interface supportYes
Bus communicationYes
3RK1322-1CS02-0AA4 — Electrical
ParameterValue
Voltage typeDC
3RK1322-1CS02-0AA4 — Environmental
ParameterValue
Ingress protection (IP)IP65
Ambient operating temperature-25 ... +55 °C
3RK1322-1CS02-0AA4 — Mechanical
ParameterValue
Width120 mm
Depth190 mm
Height270 mm
3RK1322-1CS02-0AA4 — Specifications
ParameterValue
Type Of The Motor Protectionbimetal

Product details

AS-Interface compact direct starter, IP65, 1.8–2.5 A

The Siemens 3RK1322-1CS02-0AA4 is an AS-Interface compact direct starter — a self-contained motor start/stop unit in an IP65 enclosure, rated for 0.9 kW at AC-3 / 400 V with a setting range of 1.8 to 2.5 A. It's an electromechanical DOL starter with bimetal motor protection and integrated short-circuit protection via circuit-breakers, so it handles both overload and fault current in one package. Communication is over AS-Interface (AS-i) protocol, not PROFIBUS DP, so this unit plugs directly into an AS-i yellow cable loop. It carries two integrated inputs for local sensors (e.g., limit switches or emergency-stop buttons) and a motor brake output rated at 500 V DC / 1 A — useful for holding brakes on vertical-axis motors. The 9-pole motor outgoing feeder and 9-pole power connection mean the wiring harness is pre-configured; you terminate the AS-i flat cable and the motor cable, not individual control wires. For a distributed starter mounted on a machine frame rather than inside a switchgear panel, that SCCR headroom is the difference between a coordinated trip and a blown-open housing.

Dimensions are 120 mm wide × 270 mm high × 190 mm deep. The IP65 housing is designed for direct machine-mounting — bolt it to the frame or a mounting plate, run the AS-i flat cable and motor cable, and you're done. No DIN rail, no separate contactor/enclosure assembly. The equipment marking per DIN EN 61346-2 is 'Q', the standard identifier for motor-starter equipment in schematic diagrams.

Frequently asked questions

What is the setting range and motor power rating?

The setting range is 1.8 to 2.5 A, and the motor power rating is 0.9 kW at AC-3 / 400 V.

What communication protocol does this starter use?

It uses AS-Interface (AS-i) protocol. It does not support PROFIBUS DP.

Where can I buy 3RK1322-1CS02-0AA4?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Does it include a motor brake output?

Yes, it has a product component motor brake output rated at 500 V DC / 1 A.