Skip to main content
Siemens 3RK1322-1CS02-1AA3 — Remote I/O & Fieldbus Modules

Siemens 3RK1322-1CS02-1AA3 AS-i Reversing Starter, 0.9 kW, I

MPN3RK1322-1CS02-1AA3

Siemens AS-i compact reversing starter, IP65, electromechanical, 1.8-2.5 A setting range, AC-3 0.9 kW / 400 V, with integrated brake contact, 9-pole motor feeder, 2 inputs.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RK1322-1CS02-1AA3 — Identification
ParameterValue
Product designreversing starter
3RK1322-1CS02-1AA3 — Communication
ParameterValue
PROFIBUS DP supportNo
AS-Interface supportYes
Bus communicationYes
3RK1322-1CS02-1AA3 — Electrical
ParameterValue
Voltage typeDC
3RK1322-1CS02-1AA3 — Environmental
ParameterValue
Ingress protection (IP)IP65
Ambient operating temperature-25 ... +55 °C
3RK1322-1CS02-1AA3 — Mechanical
ParameterValue
Width120 mm
Depth190 mm
Height270 mm
3RK1322-1CS02-1AA3 — Specifications
ParameterValue
Type Of The Motor Protectionbimetal

Product details

The Siemens 3RK1322-1CS02-1AA3 is an AS-i compact reversing starter in an IP65 enclosure, rated for 0.9 kW at 400 V AC-3 duty with a setting range of 1.8 to 2.5 A. It integrates a bimetal motor protection relay, electromechanical switching contacts, and a motor brake output, all in one field-mounted package that communicates over AS-interface. The IP65 rating means the enclosure and connectors withstand washdown — this starter is designed for direct mounting on conveyors, packaging machines, or material handling sections where running control wiring back to a panel is impractical. The reversing contactor pair handles forward/reverse motor control, and the integrated brake output handles the holding brake on vertical-axis drives.

The AC-3 rating of 0.9 kW at 400 V defines the maximum induction motor load this starter can switch under full-load starting conditions — that covers small conveyors, agitators, and fan drives up to that power. The bimetal overload relay is set via the 1.8 to 2.5 A range, matching the motor FLA. The electromechanical contactor design gives you visual confirmation of state and no leakage current in the off state — unlike a solid-state alternative, this part is a direct replacement for traditional reversing starters, just packaged for distributed mounting.

The enclosure measures 270 mm high by 120 mm wide by 190 mm deep — sized for direct machine mounting via the integrated flanges. Main circuit connections use tab terminals; the AS-i bus connection and the two integrated inputs handle the control and feedback wiring. The 9-pole motor outgoing feeder and 9-pole power connection mean you land the motor cable and supply cable directly on the unit, not through a separate junction box. The AS-interface protocol onboard eliminates a separate bus coupler — the starter appears as a single node on the AS-i network, and the two integrated inputs can read limit switches or sensors directly.

Frequently asked questions

What is the SCCR and why does it matter?

The maximum short-circuit breaking capacity is 50 kA at 400 V. That is a high interrupting rating for a compact reversing starter — it means the unit can clear a fault up to that level without needing upstream protection to operate, which simplifies panel coordination and allows installation on high-fault-capacity systems.

Does this starter include a brake output?

Yes, the product component list includes a motor brake output. That is the additional contact set for controlling a DC or AC holding brake on vertical-axis motors — common on hoists, elevators, or vertical conveyors.

What is the motor protection type?

The motor protection uses a bimetal overload relay, adjustable across the 1.8 to 2.5 A setting range. Bimetal relays provide thermal-model protection that tracks motor heating and cooling — they are the standard choice for reversing starters in this power class.

MPN
3RK1322-1CS02-1AA3