Specifications

3RK1322-1DS02-0AA0 specifications
ParameterValue
IP ratingIP65
Temp operating max55 °C
Temp operating min-25 °C
Depth190 mm
Width120 mm
Height270 mm

Product details

AS-i Compact Starter for Distributed Motor Control

The Siemens 3RK1322-1DS02-0AA0 is an AS-interface compact starter — a direct-on-line (DOL) motor starter in an IP65 enclosure designed for distributed control architectures. The setting range of 2.2 to 3.2 A means the overload relay is factory-set for that window; you adjust the bimetal trip within it to match the motor full-load current. The IP65 protection class means the enclosure withstands hose-directed water and dust ingress — suitable for washdown zones in food processing, automotive assembly, or outdoor material handling where a central panel isn't practical. The electromechanical switching contact and bimetal motor protection are field-proven technology; no firmware to corrupt, no configuration to lose on power cycle.

Fieldbus Integration and I/O

This starter communicates via AS-interface protocol, not PROFIBUS DP. That makes it a node on a two-wire AS-i bus carrying both power and data — common in distributed I/O architectures where you want motor control and sensor feedback on the same cable. The two integrated inputs accept limit switches, proximity sensors, or emergency-stop contacts directly into the starter, reducing junction box wiring. The 9-pole motor outgoing feeder and 9-pole power connection handle the motor cable and control wiring through a single connector interface.

Short-Circuit Coordination and Breaking Capacity

The maximum short-circuit breaking capacity (Icu) is 50,000 A at 400 V — a high-fault rating that allows this starter to be installed on industrial networks with substantial available fault current without requiring upstream current-limiting fuses. The short-circuit protection design uses circuit-breakers, meaning the coordination between the upstream breaker and the starter's bimetal overload is defined; verify the manufacturer's coordination tables for your specific breaker model.

MPN