Skip to main content
Siemens 3RK1395-6KS41-0AD3 — Remote I/O & Fieldbus Modules

Siemens 3RK1395-6KS41-0AD3 SIRIUS Motor Starter, 2 A at 400

MPN3RK1395-6KS41-0AD3
NRND

Siemens SIRIUS direct motor starter, 3RK1395-6KS41-0AD3, rated 2 A at 400 V AC, 0.75 kW, IP65, selectable trip classes 5/10/15/20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RK1395-6KS41-0AD3 — Identification
ParameterValue
Product designationMotor starters
Product designdirect starter
3RK1395-6KS41-0AD3 — Communication
ParameterValue
PROFIBUS DP supportNo
PROFINET supportNo
AS-Interface supportNo
AS-Interface supportNo
Bus communicationYes
3RK1395-6KS41-0AD3 — I/O
ParameterValue
Digital inputs4
Digital input signals4
Digital output signals2
Digital inputs parameterizableYes
Digital outputs parameterizableYes
3RK1395-6KS41-0AD3 — Electrical
ParameterValue
Rated value (DC)20.4 ... 28.8 V
Control supply voltage typeDC
Rated surge voltage6 000 V
Adjustable Current Response Value Current Of The Current-Dependent Overload Release0.15 ... 2 A
Operating Voltage Rated Value200 ... 440 V
Number Of Poles For Main Current Circuit3
3RK1395-6KS41-0AD3 — Environmental
ParameterValue
Ingress protection (IP)IP65
Operating temperature range-25 ... +55 °C
Storage temperature range-40 ... +70 °C
Shock resistance12g / 11 ms
Pollution degree3
3RK1395-6KS41-0AD3 — Mechanical
ParameterValue
Width294 mm
Depth148 mm
Height215 mm
Mounting methodscrew fixing
3RK1395-6KS41-0AD3 — Specifications
ParameterValue
At 400 V rated value0.75 kW
At AC-3 at 400 V rated value2 A
Reverse StartingNo
Type Of The Motor Protectionfull motor protection
Trip ClassCLASS 5, 10, 15, 20

Product details

Product Overview and Key Ratings

The Siemens SIRIUS 3RK1395-6KS41-0AD3 is a direct motor starter designed for fixed-speed motor control in industrial automation. It is rated for a motor power of 0.75 kW at 400 V AC and carries a rated operational current of 2 A at 400 V AC, making it suitable for small induction motors driving pumps, fans, or conveyors. The unit is also rated at 0.7 hp at 460/480 V and 1 hp at 575/600 V, covering common North American voltage levels. The starter offers selectable trip classes (CLASS 5, 10, 15, 20), allowing the overload protection curve to be matched to the motor's starting characteristics — a Class 10 setting for short acceleration times, Class 20 for high-inertia loads. This flexibility is critical for protecting the motor without nuisance tripping during startup. The enclosure is designed for screw fixing and can be mounted vertically, horizontally, or flat, giving panel builders layout flexibility.

Electrical and Control Interface

The starter is powered by a 24 V DC control supply, with a permissible range of 20.4 to 28.8 V DC. This is a standard industrial voltage, compatible with most PLC and control system outputs. The unit provides 4 digital inputs and 2 digital outputs for integration into a control circuit, allowing remote start/stop and status feedback without additional I/O modules. The main circuit connection uses a plug according to ISO 23570 (HAN Q4/2), a standardized industrial connector that simplifies wiring and replacement. The unit does not support PROFINET, PROFIBUS DP, or AS-Interface protocols — control is via hardwired digital signals only. On-delay time is 85 ms and off-delay time is 65 ms, providing predictable switching behavior for sequencing logic. The starter supports direct start only; reverse starting is not available, so a separate reversing contactor is required for bidirectional motor control.

It withstands shock loads of 12g for 11 ms and vibration of 7 mm at 2g, per the datasheet, making it robust for installation on machinery or in mobile equipment. This is typical for control panels in factory floors or process plants. Physical dimensions: 294 mm width, 215 mm height, 148 mm depth. The recommended mounting orientation is horizontal, though vertical and flat positions are also permitted. The unit is not designed for on-site operation — it is intended for remote control via the digital inputs.

The unit is not a direct cross-reference for the 3RT5065-6NF36 or 3RT1044-1FB46 — those are contactors, not integrated motor starters with overload protection and I/O.

Frequently asked questions

What is the rated motor power for 3RK1395-6KS41-0AD3 at 400 V?

The rated motor power is 0.75 kW at 400 V AC, with a rated operational current of 2 A at 400 V AC.

What trip classes are available on this motor starter?

The starter offers selectable trip classes CLASS 5, 10, 15, and 20, allowing the overload protection to be tuned to the motor's starting profile.

Where can I buy 3RK1395-6KS41-0AD3?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the IP rating of 3RK1395-6KS41-0AD3?

The enclosure is rated IP65, meaning it is dust-tight and protected against low-pressure water jets from any direction.

MPN
3RK1395-6KS41-0AD3