Siemens 3RK1395-6KS41-2AD5 — Remote I/O & Fieldbus Modules

Siemens 3RK1395-6KS41-2AD5 SIRIUS Motor Starter, 0.75 kW at

MPN3RK1395-6KS41-2AD5
NRND

Siemens SIRIUS, direct motor starter, 3RK1395-6KS41-2AD5, 0.75 kW at 400 V, IP65, 4 digital inputs, 2 digital outputs, trip classes 5/10/15/20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RK1395-6KS41-2AD5 — Identification
ParameterValue
Product designationMotor starters
Product designdirect starter
3RK1395-6KS41-2AD5 — Communication
ParameterValue
PROFIBUS DP supportNo
PROFINET supportNo
AS-Interface supportNo
AS-Interface supportNo
Bus communicationYes
3RK1395-6KS41-2AD5 — I/O
ParameterValue
Digital inputs4
Digital input signals4
Digital output signals2
Digital inputs parameterizableYes
Digital outputs parameterizableYes
3RK1395-6KS41-2AD5 — Electrical
ParameterValue
Rated value (DC)20.4 ... 28.8 V
Control supply voltage typeDC
Rated surge voltage6 000 V
Adjustable Current Response Value Current Of The Current-Dependent Overload Release0.15 ... 2 A
Operating Voltage Rated Value200 ... 440 V
Number Of Poles For Main Current Circuit3
3RK1395-6KS41-2AD5 — Environmental
ParameterValue
Ingress protection (IP)IP65
Operating temperature range-25 ... +55 °C
Storage temperature range-40 ... +70 °C
Shock resistance12g / 11 ms
Pollution degree3
3RK1395-6KS41-2AD5 — Mechanical
ParameterValue
Width294 mm
Depth148 mm
Height215 mm
Mounting methodscrew fixing
3RK1395-6KS41-2AD5 — Specifications
ParameterValue
At 400 V rated value0.75 kW
At AC-3 at 400 V rated value2 A
Reverse StartingNo
Type Of The Motor Protectionfull motor protection
Trip ClassCLASS 5, 10, 15, 20

Product details

The Siemens 3RK1395-6KS41-2AD5 is a SIRIUS direct motor starter, rated 0.75 kW at 400 V and 2 A at 400 V AC. It's a self-contained unit with 4 digital inputs and 2 digital outputs, housed in an IP65 enclosure — meaning it can sit right on the machine frame, not just in a clean panel. Supply is 24 V DC (20.4...28.8 V).

Trip class and motor protection

This starter offers selectable trip classes 5, 10, 15, and 20. That range covers fast-protection for submersible pumps (class 5) up to high-inertia loads like centrifuges (class 20). You set it to match the motor's thermal damage curve — not a one-size-fits-all overload relay.

Mounting is screw fixing; the unit can go vertical, horizontal, or flat. Recommended orientation is horizontal for best heat dissipation. Dimensions are 294 mm wide, 215 mm high, 148 mm deep — that's a sizable footprint, so check your gland plate and DIN-rail space before committing.

MPN