Skip to main content
Siemens 3RK1395-6KS41-3AD3 — Remote I/O & Fieldbus Modules

Siemens SIRIUS 3RK1395-6KS41-3AD3 reversing starter, 0.75 kW

MPN3RK1395-6KS41-3AD3
NRND

Siemens SIRIUS reversing starter, 3RK1395-6KS41-3AD3, 24 V DC, 0.75 kW at 400 V, 2 A, IP65, Trip Class 5/10/15/20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RK1395-6KS41-3AD3 — Identification
ParameterValue
Product designationMotor starters
Product designreversing starter
3RK1395-6KS41-3AD3 — Communication
ParameterValue
PROFIBUS DP supportNo
PROFINET supportNo
AS-Interface supportNo
AS-Interface supportNo
Bus communicationYes
3RK1395-6KS41-3AD3 — I/O
ParameterValue
Digital inputs4
Digital input signals4
Digital output signals2
Digital inputs parameterizableYes
Digital outputs parameterizableYes
3RK1395-6KS41-3AD3 — Electrical
ParameterValue
Rated value (DC)20.4 ... 28.8 V
Control supply voltage typeDC
Rated surge voltage6 000 V
Adjustable Current Response Value Current Of The Current-Dependent Overload Release0.15 ... 2 A
Operating Voltage Rated Value200 ... 440 V
Number Of Poles For Main Current Circuit3
3RK1395-6KS41-3AD3 — Environmental
ParameterValue
Ingress protection (IP)IP65
Operating temperature range-25 ... +55 °C
Storage temperature range-40 ... +70 °C
Shock resistance12g / 11 ms
Pollution degree3
3RK1395-6KS41-3AD3 — Mechanical
ParameterValue
Width294 mm
Depth148 mm
Height215 mm
Mounting methodscrew fixing
3RK1395-6KS41-3AD3 — Specifications
ParameterValue
At 400 V rated value0.75 kW
At AC-3 at 400 V rated value2 A
Reverse StartingYes
Type Of The Motor Protectionfull motor protection
Trip ClassCLASS 5, 10, 15, 20

Product details

The Siemens SIRIUS 3RK1395-6KS41-3AD3 is a reversing starter designed for motor control in industrial automation. It integrates a contactor and overload relay in a single IP65-rated enclosure, ready for direct-on-line reversing of three-phase motors up to 0.75 kW at 400 V (2 A). The 24 V DC control supply keeps it compatible with standard PLC outputs. Trip Class is selectable between 5, 10, 15, and 20, letting you match the overload protection to the motor's thermal time constant — a Class 10 setting is typical for standard induction motors, while Class 20 suits high-inertia loads like fans or centrifuges.

This is a reversing starter — it includes two contactors mechanically interlocked to swap motor phase rotation, so one unit handles forward/reverse control without external interlocking relays. Four digital inputs and two digital outputs are onboard for local pushbuttons or a PLC, reducing wiring to a single 24 V DC supply and a motor cable.

Mounting is by screw fixing; the enclosure accepts vertical, horizontal, or flat orientation. The main circuit connects via a HAN Q4/2 plug per ISO 23570, so pre-wired harnesses or panel-mounted receptacles mate directly. Dimensions are 294 mm wide, 215 mm high, 148 mm deep — plan for a 300 mm wide gland plate or backplate cutout. Vibration resistance is 7 mm / 2g, shock resistance 12g / 11 ms, suitable for machine-mounted duty.

Frequently asked questions

What are the key ratings for this reversing starter?

Rated 0.75 kW at 400 V AC (2 A) for motor duty. Control supply is 24 V DC (20.4 to 28.8 V). Trip Class is selectable among 5, 10, 15, and 20. Enclosure is IP65. Dimensions: 294 x 215 x 148 mm.

What is the supply voltage range?

The control supply is 24 V DC, with a permissible range of 20.4 to 28.8 V DC.

What is the depth of this unit?

The depth is 148 mm.

What is the width of this unit?

The width is 294 mm.

MPN
3RK1395-6KS41-3AD3