Skip to main content
Siemens 3RK1400-1CE01-0AA2 — Remote I/O & Fieldbus Modules

Siemens 3RK1400-1CE01-0AA2 AS-Interface Slave, 4DI/4DO, IP20

MPN3RK1400-1CE01-0AA2

Siemens SlimLine S22.5 AS-Interface standard slave, 4 digital inputs / 4 digital outputs, IP20, 45 mm wide, DIN-rail or wall mount, requires external 20-30 VDC AUX supply for outputs.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RK1400-1CE01-0AA2 — Identification
ParameterValue
Product designSlimLine S22.5 - I/O modules for operation in the control cabinet
3RK1400-1CE01-0AA2 — Communication
ParameterValue
AS-Interface supportYes
3RK1400-1CE01-0AA2 — I/O
ParameterValue
Digital inputs4
3RK1400-1CE01-0AA2 — Environmental
ParameterValue
Ingress protection (IP)IP20
Operating temperature range-25 ... +70°C
Storage temperature range-40 ... +85°C
3RK1400-1CE01-0AA2 — Mechanical
ParameterValue
Width45mm
Depth86mm
Height106mm
Mounting method35 mm standard rail mounting or wall mounting using push-in lugs

Product details

AS-Interface I/O module for control-cabinet integration

The Siemens 3RK1400-1CE01-0AA2 is a SlimLine S22.5 AS-Interface standard slave packing 4 digital inputs and 4 digital outputs into a 45 mm wide IP20 housing that snaps onto 35 mm DIN rail or mounts directly to a panel wall. An external auxiliary supply (AUX POWER) of 20 to 30 V DC is required for the output circuits, and must comply with VDE 0106 (PELV), protection class III — the module does not derive output power from the AS-Interface bus alone.

I/O mapping and diagnostics

The four I/O channels are mapped as D0 (IN1/OUT1), D1 (IN2/OUT2), D2 (IN3/OUT3), and D3 (IN4/OUT4). I/O configuration is set to 7, addressing is done via the front addressing socket. Diagnostics are visible through three LEDs: green for AS-Interface communication, yellow per-channel for I/O status, and red for fault indication. A built-in watchdog monitors bus communication. Short-circuit protection and induction protection are both built-in, so external fusing or snubbers on the output side are not required for basic protection.

Fastening is via 35 mm standard rail mounting or wall mounting using push-in lugs. Connection technology supports 2- and 3-wire sensors. Solid wire: 1 x (0.5–4) mm² or 2 x (0.5–2.5) mm²; with end sleeve: 1 x (0.5–2.5) mm² or 2 x (0.5–1.5) mm². AWG solid or stranded: 2 x (20–14).

Frequently asked questions

What is the D0 (IN1/OUT1) channel on this module?

D0 is the first I/O channel, mapped as IN1 and OUT1 on the 3RK1400-1CE01-0AA2.

What compliance documentation is available for 3RK1400-1CE01-0AA2?

The module requires an external AUX supply compliant with VDE 0106 (PELV), protection class III. Standard Siemens declarations (RoHS, REACH, CE) apply; specific certificates should be requested at order.

MPN
3RK1400-1CE01-0AA2