Skip to main content
Siemens 3RK1400-1CG00-0AA2 — Remote I/O & Fieldbus Modules

Siemens 3RK1400-1CG00-0AA2 AS-i SlimLine S22.5, 4I/4O

MPN3RK1400-1CG00-0AA2

Siemens AS-Interface standard slave, SlimLine S22.5, 4 digital inputs / 4 digital outputs, IP20, 35 mm DIN rail mount, current lifecycle.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RK1400-1CG00-0AA2 — Identification
ParameterValue
Product designSlimLine S22.5 - I/O modules for operation in the control cabinet
3RK1400-1CG00-0AA2 — Communication
ParameterValue
AS-Interface supportYes
3RK1400-1CG00-0AA2 — I/O
ParameterValue
Digital inputs4
3RK1400-1CG00-0AA2 — Environmental
ParameterValue
Ingress protection (IP)IP20
Operating temperature range-25 ... +70°C
Storage temperature range-40 ... +85°C
3RK1400-1CG00-0AA2 — Mechanical
ParameterValue
Width45mm
Depth86mm
Height108mm
Mounting method35 mm standard rail mounting or wall mounting using push-in lugs

Product details

AS-i standard slave, 4 inputs / 4 outputs, SlimLine S22.5

The Siemens 3RK1400-1CG00-0AA2 is a standard AS-Interface slave module in the SlimLine S22.5 form factor, packing 4 digital inputs and 4 digital outputs into a 45 mm wide housing that clips onto 35 mm DIN rail or mounts to a backplate with push-in lugs. Each input is PNP transistor type, 20-30 VDC, with a signal-1 minimum of 5 mA and signal-0 maximum of 1.5 mA — typical for standard 3-wire sensors. The outputs are solid-state, delivering 22-24 VDC at 24 V nominal, with a 4 A aggregate current ceiling across all four channels. Critical for panel wiring: an external auxiliary supply (AUX POWER) of 20-30 VDC is required to power the output circuits, and it must comply with VDE 0106 (PELV), protection class III — that's a separate feed, not drawn from the AS-i bus. The module carries built-in short-circuit protection and induction protection, plus a watchdog that monitors bus communication. Status is visible via green AS-Interface LED, yellow I/O LEDs per channel, and a red fault LED.

Mounting and connection

Fastens onto 35 mm standard DIN rail or wall-mounts using the push-in lugs. Spring-loaded terminals accept 2 x (0.25-1.5) mm² solid or stranded, or 2 x (0.25-1) mm² with end sleeves; AWG 24-16 solid or stranded. A detachment tool for the spring terminals is listed under accessories. IP20 protection — intended for clean, dry cabinet environments, not washdown or outdoor locations.

Frequently asked questions

What is the 3RK1400-1CG00-0AA2 used for?

It is an AS-Interface standard slave module that connects 4 digital inputs and 4 digital outputs to an AS-i bus network, typically used in distributed I/O for conveyor, packaging, or material-handling lines inside a control cabinet.

Does the 3RK1400-1CG00-0AA2 need a separate power supply?

Yes, an external auxiliary supply of 20-30 VDC is required for the output circuits, separate from the AS-i bus power, and must comply with VDE 0106 (PELV), protection class III.

Where can I buy the 3RK1400-1CG00-0AA2?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RK1400-1CG00-0AA2