Specifications

3RK1402-3LG02-0AA1 specifications
ParameterValue
Product type3 inputs / 2 relay outputs
Input voltage26.5 ... 31.6 V
IP ratingIP20
Mountingstandard rail
Width45 mm

Product details

AS-i Load Feeder — 3 Inputs, 2 Relay Outputs

The 3RK1402-3LG02-0AA1 is a Siemens AS-Interface load feeder module with 3 digital inputs and 2 relay outputs, designed for the 40+60 mm busbar system. It is a standard slave on the AS-i network, drawing 8 to 12 mA from the bus for its own electronics. Inputs are 2-conductor DC, accepting 26.5 to 31.6 V, with a minimum signal-1 current of 6 mA per channel. The relay outputs switch up to 3 A in AC-15 duty (230 V AC) or 0.1 A in DC-13 at 220 V — the aggregate thermal current Ith is 3 A. Wiring uses spring-loaded terminals for I/O (0.8 to 2.5 mm² flexible without end sleeves) and insulation displacement for the AS-i and auxiliary power connection (0.5 to 0.75 mm² flexible). The module snaps onto standard DIN rail and is IP20 rated.

Lifecycle Status — Phased Out, Sourced to Order

No official successor order code is listed by Siemens for this module. For BOM continuity, a functional cross-reference to a current AS-i load feeder may be needed — confirm fit with the panel layout and AS-i master compatibility before specifying a replacement.

Integration Notes — Panel Fit and Addressing

The module is 45 mm wide and mounts on standard DIN rail. It uses the AS-i bus for communication and auxiliary power via a 5-pole connector (0.5 to 2.5 mm², AWG 28 to 12). The built-in watchdog monitors bus communication; the module retains its last address after the 15th addressing procedure. Status LEDs on the front indicate output activation, AS-i communication OK, communication fault, and station address = 0 (module not addressed). The ID code is F. Operating temperature range is 0 to 55 °C; storage range is -40 to +85 °C. The relay outputs are not short-circuit proof and have no built-in short-circuit protection — external fusing or a protective device must be added per the load circuit. Polarity reversal protection is also not required per the design.