Skip to main content
Siemens 3RK1402-3LG02-0AA1 — Remote I/O & Fieldbus Modules

Siemens 3RK1402-3LG02-0AA1 AS-i Load Feeder

MPN3RK1402-3LG02-0AA1

Siemens 3RK1402-3LG02-0AA1 AS-i load feeder module, 3 inputs / 2 relay outputs, 45 mm width, IP20, spring-loaded terminals.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RK1402-3LG02-0AA1 — Identification
ParameterValue
Product designload feeder modules, IP20

I/O

3RK1402-3LG02-0AA1 — I/O
ParameterValue
Digital inputs3

Environmental

3RK1402-3LG02-0AA1 — Environmental
ParameterValue
Ingress protection (IP)IP20
Operating temperature range0 ... 55°C
Storage temperature range-40 ... +85°C

Mechanical

3RK1402-3LG02-0AA1 — Mechanical
ParameterValue
Width45mm
Mounting methodstandard rail

Product details

AS-i Load Feeder — 3 Inputs, 2 Relay Outputs

The 3RK1402-3LG02-0AA1 is a Siemens AS-Interface load feeder module with 3 digital inputs and 2 relay outputs, designed for the 40+60 mm busbar system. It is a standard slave on the AS-i network, drawing 8 to 12 mA from the bus for its own electronics. Inputs are 2-conductor DC, accepting 26.5 to 31.6 V, with a minimum signal-1 current of 6 mA per channel. The relay outputs switch up to 3 A in AC-15 duty (230 V AC) or 0.1 A in DC-13 at 220 V — the aggregate thermal current Ith is 3 A. Wiring uses spring-loaded terminals for I/O (0.8 to 2.5 mm² flexible without end sleeves) and insulation displacement for the AS-i and auxiliary power connection (0.5 to 0.75 mm² flexible). The module snaps onto standard DIN rail and is IP20 rated.

Lifecycle Status — Phased Out, Sourced to Order

No official successor order code is listed by Siemens for this module. For BOM continuity, a functional cross-reference to a current AS-i load feeder may be needed — confirm fit with the panel layout and AS-i master compatibility before specifying a replacement.

Integration Notes — Panel Fit and Addressing

The module is 45 mm wide and mounts on standard DIN rail. It uses the AS-i bus for communication and auxiliary power via a 5-pole connector (0.5 to 2.5 mm², AWG 28 to 12). The built-in watchdog monitors bus communication; the module retains its last address after the 15th addressing procedure. Status LEDs on the front indicate output activation, AS-i communication OK, communication fault, and station address = 0 (module not addressed). The ID code is F. Operating temperature range is 0 to 55 °C; storage range is -40 to +85 °C. The relay outputs are not short-circuit proof and have no built-in short-circuit protection — external fusing or a protective device must be added per the load circuit. Polarity reversal protection is also not required per the design.

Frequently asked questions

What is the output current rating of 3RK1402-3LG02-0AA1?

The relay outputs are rated 3 A in AC-15 duty (230 V AC) and 0.1 A in DC-13 at 220 V. The aggregate thermal current Ith is 3 A.

What wiring connections does this module use?

I/O wiring uses spring-loaded terminals accepting 0.8 to 2.5 mm² flexible wire without end sleeves. The AS-i and auxiliary power connection uses insulation displacement terminals for 0.5 to 0.75 mm² flexible wire.

MPN
3RK1402-3LG02-0AA1