Skip to main content
Siemens 3RK1901-1NR11 — Remote I/O & Fieldbus Modules

Siemens 3RK1901-1NR11 AS-i M12 Branch, 4A, IP67/68/69K

MPN3RK1901-1NR11

Siemens AS-Interface accessories, 3RK1901-1NR11, M12 branch cable, 1 m, 4 A, IP67/68/69K.

$62.38Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RK1901-1NR11 — Identification
ParameterValue
Product designAS-i M12 feeder, AS-i without Uaux, 1 m cable
3RK1901-1NR11 — Other specifications
ParameterValue
Notecable must not end in the feeder
FunctionAS-i flat cable transition to M12
ConnectionM12 cable box 1 m
Type of deviceAS-Interface accessories
Type of mountingscrew fixing
Operating temperature-25 ... +75°C
IP ratingIP67/68/69K
Contacts load rating max4A
Inputs socket assignment1 = AS-i "+" 3=AS-i "-"
Type of electrical connectioninsulation piercing method for AS-Interface flat cable
Ambient temperature during storage-25 ... +85°C
Operating voltage according to AS-Interface spezification26.5 ... 31.6V

Product details

The Siemens 3RK1901-1NR11 is an AS-Interface M12 branch cable assembly — a transition from the AS-i flat cable to an M12 socket, with a 1 m cable and an angled M12 connector. It carries the AS-i signal and power (26.5–31.6 V per the AS-Interface specification) but no auxiliary Uaux supply. Rated for 4 A continuous, it feeds a single actuator or sensor node on the bus.

Washdown-ready deployment

IP67/68/69K means the connector body and cable entry survive high-pressure hot-water washdown — food-and-bev or chemical processing lines where standard IP67 connectors fail. Screw fixing secures the branch point to a bracket or panel; the insulation-piercing method taps the flat cable without stripping it.

Cable routing constraint

The manufacturer note states the cable must not end in the feeder — meaning the free end of this 1 m pigtail cannot terminate inside the AS-i power supply or gateway housing. It must connect to a device or a termination cap. Plan the drop length accordingly.

Listed as current production.

Frequently asked questions

What is the function of 3RK1901-1NR11?

It transitions from the AS-i flat cable to an M12 connector, providing a 1 m branch with an angled M12 cable socket.

What does the note 'cable must not end in the feeder' mean?

The free end of the 1 m cable cannot terminate inside the AS-i power supply or gateway housing; it must connect to a device or termination cap.

What is the IP rating and where can this be used?

IP67/68/69K — suitable for washdown environments such as food-and-bev or chemical processing lines.

Where can I buy 3RK1901-1NR11?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN
3RK1901-1NR11