Skip to main content
Siemens 3RK1908-0AP00-0CH0 — Remote I/O & Fieldbus Modules

Siemens 3RK1908-0AP00-0CH0 BaseUnit, 24 V DC, 7 A, Push-in

MPN3RK1908-0AP00-0CH0
Active

Siemens SIMATIC 3RK1908-0AP00-0CH0 BaseUnit, for AC feed in, 24 V DC, 7 A, push-in spring-loaded terminals, 75 x 30 x 215 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RK1908-0AP00-0CH0 — Identification
ParameterValue
Product designationBaseUnit
Product designFor AC feed in
3RK1908-0AP00-0CH0 — I/O
ParameterValue
Digital inputs0
3RK1908-0AP00-0CH0 — Electrical
ParameterValue
Rated surge voltage6 kV
Operating Voltage Rated Value500 V
Number Of Poles For Main Current Circuit3
3RK1908-0AP00-0CH0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; For derating see manual
Storage temperature range-40 ... +70 °C
Shock resistance6g / 11 ms
Pollution degree2
3RK1908-0AP00-0CH0 — Mechanical
ParameterValue
Width30 mm
Depth75 mm
Height215 mm
Mounting methodstandard rail

Product details

BaseUnit for AC feed in — what it carries

The 3RK1908-0AP00-0CH0: This is a SIMATIC BaseUnit (product designation BaseUnit) designed specifically for AC feed in — it distributes the AC supply voltage to the I/O modules mounted above it on the standard DIN rail. The supply voltage is 24 V DC, rated 20.4 V minimum to 28.8 V maximum, so it matches the standard 24 V DC control supply found in every Siemens panel. The screwdriver tip needed is a standard slot 0.6 mm x 3.5 mm — no special tooling required for field termination. Ampacity maximum is 7 A across the bus; the rated operating voltage and insulation voltage are both 500 V, with 500 V isolation between main and auxiliary circuits. Surge voltage resistance is 6 kV, which puts this BaseUnit in the pollution degree 2 environment — typical for clean, climate-controlled industrial panels.

Mounting position can be vertical or horizontal; the fastening method is standard rail (DIN rail). Relative humidity during operation is 10 to 95 %, and air pressure range is 900 to 1060 hPa per SN 31205. Vibration resistance is 15 mm at 6 Hz and 2g up to 500 Hz; shock resistance is 6g for 11 ms — this BaseUnit holds up in machinery with moderate vibration profiles. Clearance required above and below the unit is 50 mm each way for airflow and wiring access — factor this into the panel layout. The IEC 81346-2 reference code is Q, which designates it as a switching device in the equipment function classification.

Lifecycle and compliance status

Substance prohibitance date is 04/15/2016, which aligns with the RoHS compliance cutoff — the BaseUnit meets the RoHS substance restrictions effective from that date. No additional compliance documentation (UL, CSA, CE) is listed in the spec record, so confirm jurisdiction-specific approvals with the factory if required for your panel certification.

Frequently asked questions

What terminal type does 3RK1908-0AP00-0CH0 use?

Both the main current circuit and the auxiliary/control circuit use push-in spring-loaded terminals (push-in terminal type). A standard slot screwdriver 0.6 mm x 3.5 mm is needed for release.

MPN
3RK1908-0AP00-0CH0