Siemens 3RK2400-1BQ30-0AA3 — Remote I/O & Fieldbus Modules

Siemens 3RK2400-1BQ30-0AA3 K20 Field I/O Module, 2 Inputs /

MPN3RK2400-1BQ30-0AA3
Active

Siemens K20 field I/O module, AS-Interface A/B slave, 2 digital inputs + 2 digital outputs, PNP, 1 A max, IP67, 20 mm wide.

$123.19Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RK2400-1BQ30-0AA3 — Identification
ParameterValue
Product designdigital I/O modules for operation in the field, IP67 - K20
3RK2400-1BQ30-0AA3 — I/O
ParameterValue
Digital inputs2
3RK2400-1BQ30-0AA3 — Environmental
ParameterValue
Ingress protection (IP)IP67
Operating temperature range-25 ... +70 °C
Storage temperature range-40 ... +85 °C
Shock resistance15g / 11 ms
3RK2400-1BQ30-0AA3 — Mechanical
ParameterValue
Width20 mm
Depth45 mm
Height108 mm
Mounting methodno mounting plate required

Product details

The Siemens 3RK2400-1BQ30-0AA3 is a K20 field I/O module for AS-Interface networks, configured as an A/B slave with 2 digital inputs and 2 digital outputs. It's built for distributed I/O in the field, meaning it sits on the machine frame or conveyor line rather than in a central cabinet — the IP67 rating confirms it withstands washdown and airborne particulates in production environments.

Each output channel is rated 1 A maximum, which governs the solenoid valves, signal lamps, or small contactor coils this module can drive directly. The input circuit uses PNP transistor technology, so it expects sourcing sensors (e.g., 3-wire proximity switches) that pull the input high when active. The module requires an external auxiliary supply of 20 to 30 V DC for the output circuits, separate from the AS-Interface bus power. That supply must comply with VDE 0106 (PELV) protection class III — a standard requirement for touch-safe low-voltage circuits in industrial control panels. Built-in short-circuit protection and induction suppression mean the module handles typical field-wiring faults without external clamp diodes or fuses per channel. The watchdog timer resets outputs if the AS-Interface master communication drops, which is standard for safety-related distributed I/O architectures.

The housing is 20 mm wide, 108 mm tall, and 45 mm deep — no mounting plate required, so it clips directly onto a DIN rail or mounts via the integrated screw holes. Two M12 I/O sockets handle the field wiring; addressing is set through the M12 female connector rather than DIP switches, which simplifies configuration but means the addressing cable must be on hand during commissioning. Shock resistance of 15 g for 11 ms means it survives typical machine vibration and handling during transport. The yellow LEDs indicate I/O state per channel; the green LED confirms the auxiliary supply is present.

Frequently asked questions

What are the key ratings for this module?

It provides 2 digital inputs and 2 digital outputs, each rated 1 A max. Inputs are PNP (sourcing), outputs are PNP switching. Requires 20-30 V DC auxiliary supply for outputs. IP67 rated.

Will this module replace a 3RT1023-1AL20 contactor in a panel?

No. The 3RT1023-1AL20 is a contactor, not an I/O module. This AS-Interface slave cannot switch motor loads or replace a contactor's power circuit. They serve different functions in the control system.