Skip to main content
Siemens 3RK2400-1DQ00-1AA3 — Remote I/O & Fieldbus Modules

Siemens 3RK2400-1DQ00-1AA3 K60 Digital I/O Module, 4 inputs

MPN3RK2400-1DQ00-1AA3
Active

Siemens K60 compact field I/O module, 3RK2400-1DQ00-1AA3, 4 inputs / 4 outputs, PNP, IP67, 20-30 VDC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RK2400-1DQ00-1AA3 — Identification
ParameterValue
Product designdigital I/O modules for operation in the field, IP67 - K60
3RK2400-1DQ00-1AA3 — I/O
ParameterValue
Digital inputs4
3RK2400-1DQ00-1AA3 — Environmental
ParameterValue
Ingress protection (IP)IP67
Operating temperature range-25 ... +85 °C
Storage temperature range-40 ... +85 °C
Shock resistance15g / 11 ms
3RK2400-1DQ00-1AA3 — Mechanical
ParameterValue
Width60 mm
Depth29 mm
Height152 mm
Mounting methodstandard rail mounting/wall mounting using mounting plate for K60 compact module

Product details

The Siemens 3RK2400-1DQ00-1AA3 is a K60 compact digital I/O module designed for field-mounting in IP67 environments. It provides 4 PNP inputs and 4 outputs, each accessible via M12 sockets, with a built-in watchdog, short-circuit protection, and induction protection. The module requires an external AUX POWER supply of 20 to 30 V DC for the output circuits, which must comply with VDE 0106 (PELV), protection class III. The input circuit itself operates on PNP transistors within the same voltage range.

Rated IP67, this module is suited for direct mounting on machinery or in wet/washdown zones without an enclosure. Dimensions are 60 mm wide, 152 mm high, and 29 mm deep. The 8 M12 sockets are pre-assigned: sockets 1-4 handle inputs (IN1 through IN4), and sockets 5-8 handle outputs (OUT1 through OUT4). Each socket's PIN 5 is a ground terminal tied to the mounting plate's grounding wrist strap via a pin.

Frequently asked questions

What is the I/O configuration of this module?

It is a 4-input / 4-output digital I/O module. The inputs are PNP type, and the outputs require a separate 20-30 VDC AUX POWER supply (PELV).

What is the IP rating and where can it be used?

IP67, meaning it is dust-tight and protected against temporary immersion in water. It can be mounted directly on machinery in wet or washdown areas without an additional enclosure.

Does this module require an external power supply?

Yes. The input circuit is powered from the sensor supply (L+ on PIN 1), but the output circuits need a separate 20-30 VDC AUX POWER supply that meets PELV requirements per VDE 0106.

MPN