Siemens 3RK4320-3DQ51-0BA2 — Motor Starters

Siemens 3RK4320-3DQ51-0BA2 SIRIUS Motor Starter

MPN3RK4320-3DQ51-0BA2

Siemens SIRIUS 3RK4320-3DQ51-0BA2 motor starter, direct starter design, AS-Interface bus communication, 1.25 A rated current at 400 V AC-3, CLASS 10 trip, IP54, DC control supply 20.4...26.4 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RK4320-3DQ51-0BA2 — Identification
ParameterValue
Product designationmotor starter MCU for AS-Interface
Main circuit poles3
BrandSIRIUS
Product design / constructiondirect starter
Reference designation (IEC 81346-2)Q
3RK4320-3DQ51-0BA2 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Overload release setting range (current)0.9 ... 1.25 A
Duty / utilization type (IEC 60947-6-2)1
3RK4320-3DQ51-0BA2 — Contacts & Control
ParameterValue
Switching contact typeelectromechanical
3RK4320-3DQ51-0BA2 — Communication
ParameterValue
AS-Interface protocol supportYes
3RK4320-3DQ51-0BA2 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Width245 mm
Height215 mm
Depth205 mm

Product details

What is the 3RK4320-3DQ51-0BA2 and where is it used?

It integrates motor protection, switching, and bus communication into one unit, so it replaces a separate contactor, overload relay, and gateway for small motor loads on an AS-Interface line. Rated 1.25 A at 400 V in AC-3 duty (switching motor loads), it is sized for fractional-horsepower motors — pumps, small conveyors, or valve actuators — where the CLASS 10 bimetal overload gives fast trip under locked-rotor conditions.

The 1.25 A AC-3 rating at 400 V is the motor-switching current — not the resistive (AC-1) rating. For a 400 V three-phase motor, this typically covers a 0.37 kW (0.5 HP) load. If your motor draws more, this starter will trip on overload or fail to break the stalled current. The 20.4...26.4 V DC control supply powers the electronics and the integrated motor brake output (if used). The brake output is rated for a DC brake — no brake control for 180 V DC or 400 V AC is built in, so external brake switching is needed for those voltages. Two digital inputs are available on the unit for local pushbuttons or limit switches, reducing wiring back to the PLC. The AS-Interface bus carries the I/O and control data over a single two-wire cable.

Dimensions are 245 mm wide × 215 mm high × 205 mm deep. Plan for side clearance to route the AS-Interface cable and the motor power wires; the IP54 housing needs no extra air gap for cooling. Short-circuit protection is provided by an upstream circuit breaker (not a fuse) — the starter itself is not a stand-alone breaker.

Frequently asked questions

Where can I buy the 3RK4320-3DQ51-0BA2?

This part is sourced to order through our independent distribution channel. Submit an RFQ for current pricing, stock availability, and lead time. Volume and blanket-order quotes are handled on request.