What this SIRIUS motor starter does on an AS-Interface line
The control supply is 20.4–26.4 V DC, and the operating voltage range is 340–440 V AC at 50/60 Hz. Two digital inputs are onboard for local control signals, and the unit includes a motor brake output — useful for holding loads on vertical conveyors or gantries. The IP54 enclosure means it's protected against dust ingress and splashing water, so it can live in a panel with moderate washdown exposure or on a machine frame in a dry industrial environment.
AS-Interface integration and mounting
This starter communicates natively over AS-Interface — no PROFIBUS or PROFINET on this variant, so it's a fit for legacy or cost-optimized AS-i lines where the bus handles both I/O and power. Dimensions are 205 mm deep, 245 mm wide, and 215 mm high — a compact footprint for a 3-pole motor starter with integrated bus communication.