Skip to main content
Siemens 3RK4320-3MQ51-0BA2 — Motor Starters

Siemens 3RK4320-3MQ51-0BA2 SIRIUS Motor Starter, 8 A

MPN3RK4320-3MQ51-0BA2

Siemens SIRIUS 3RK4320-3MQ51-0BA2 motor starter MCU for AS-Interface, direct starter, 8 A at 400 V AC-3, Class 10, IP54, 3-pole, electromechanical.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RK4320-3MQ51-0BA2 — Identification
ParameterValue
Product designationmotor starter MCU for AS-Interface
Main circuit poles3
BrandSIRIUS
Product design / constructiondirect starter
Reference designation (IEC 81346-2)Q

Protection & Tripping

3RK4320-3MQ51-0BA2 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Overload release setting range (current)5.5 ... 8 A
Duty / utilization type (IEC 60947-6-2)1

Contacts & Control

3RK4320-3MQ51-0BA2 — Contacts & Control
ParameterValue
Switching contact typeelectromechanical

Communication

3RK4320-3MQ51-0BA2 — Communication
ParameterValue
AS-Interface protocol supportYes

Mechanical & Connection

3RK4320-3MQ51-0BA2 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Width245 mm
Height215 mm
Depth205 mm

Product details

Panel fit and mounting flexibility

The 3RK4320-3MQ51-0BA2: Dimensions are 205 mm deep, 245 mm wide, and 215 mm high — the width is the dimension that drives enclosure fill on a DIN-rail layout. IP54 protection means it handles dust and splashing water — fine for panel-mount in industrial enclosures but not for direct washdown zones.

AS-Interface integration and I/O

This starter communicates over AS-Interface protocol — no PROFIBUS or PROFINET onboard, so it belongs on an AS-i network segment, not a higher-level fieldbus directly. It includes 2 digital inputs for local sensors or limit switches, and a motor brake output component for holding brakes on vertical-axis drives. Short-circuit protection is handled by upstream circuit breakers — the starter itself provides the overload protection via the bimetal relay.

Lifecycle and compliance

Substance prohibition date of 05/01/2012 aligns with RoHS compliance — the starter meets the EU RoHS directive for restricted substances. Reference code per IEC 81346-2 is Q, classifying it as a switching device in the system documentation.

MPN
3RK4320-3MQ51-0BA2