Skip to main content
Siemens 3RK4320-3MQ54-1BA2 — Motor Starters

Siemens 3RK4320-3MQ54-1BA2 SIRIUS Motor Starter, 8 A

MPN3RK4320-3MQ54-1BA2

Siemens SIRIUS 3RK4320-3MQ54-1BA2 reversing motor starter, 8 A AC-3 at 400 V, AS-Interface, IP54, 205 x 245 x 215 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RK4320-3MQ54-1BA2 — Identification
ParameterValue
Product designationmotor starter MCU for AS-Interface
Main circuit poles3
BrandSIRIUS
Product design / constructionreversing starter
Reference designation (IEC 81346-2)Q

Protection & Tripping

3RK4320-3MQ54-1BA2 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Overload release setting range (current)5.5 ... 8 A
Duty / utilization type (IEC 60947-6-2)1

Contacts & Control

3RK4320-3MQ54-1BA2 — Contacts & Control
ParameterValue
Switching contact typeelectromechanical

Communication

3RK4320-3MQ54-1BA2 — Communication
ParameterValue
AS-Interface protocol supportYes

Mechanical & Connection

3RK4320-3MQ54-1BA2 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Width245 mm
Height215 mm
Depth205 mm

Product details

AS-Interface reversing starter, 8 A AC-3

The 3RK4320-3MQ54-1BA2 is a SIRIUS reversing motor starter with integrated AS-Interface communication — it handles motor reversing and overload protection in a single enclosure, cutting panel wiring compared to a contactor-plus-overload build. Control supply is 20.4–26.4 V DC, and the unit communicates over the AS-Interface bus (no PROFIBUS or PROFINET onboard). Two digital inputs are available for local start/stop or interlock signals.

Mounting and environmental fit

IP54 enclosure means it is protected against dust ingress and splashing water — suitable for installation in control cabinets on the plant floor, but not for direct washdown zones. Ambient operating range is -25 to +50 °C. The unit includes a motor brake output (24 V DC brake control is not available on this variant — the brake output is for other voltage options). Short-circuit protection is via circuit-breakers, and the main current circuit has 3 poles.

Lifecycle and sourcing

Compliance documentation includes RoHS substance prohibitance dated 05/01/2012. The reference code per IEC 81346-2 is Q (power circuit).

MPN
3RK4320-3MQ54-1BA2